Resuspend

Resuspend[resuspendRules]primitive

generates an ExperimentSampleManipulation-compatible primitive that describes the resuspension of a sample in solvent.

Details

    Input
    Output
    Pipetting Options
    General Options
    Attributes
  • Protected

Examples

Basic Examples  (3)

Create a resuspend manipulation primitive for the resuspension of a solid sample in its current container:

Create a resuspend primitive for the resupsension of a solid sample using strings from a define primitive:

Resuspend primitives can also contain counted amounts:

Options  (38)

AnnealingTime  (1)

Specify the minimum duration for which the sample should remain in the incubator allowing the system to settle to room temperature after the IncubationTime has passe:

AspirationEquilibrationTime  (1)

Specify the delay length the pipette waits after aspirating before it is removed from the liquid:

AspirationMix  (1)

Indicate that the Diluent should be mixed before aspirating:

AspirationMixRate  (1)

Specify the speed at which liquid is aspirated and dispensed in a liquid before it is aspirated:

AspirationMixVolume  (1)

Specify the volume of the Diluent that should be aspirated and dispensed quickly to mix before aspiration:

AspirationNumberOfMixes  (1)

Specify the number of times the Diluent should be aspirated and dispensed quickly to mix before aspiration:

AspirationPosition  (1)

Specify the location from which liquid should be aspirated:

AspirationPositionOffset  (1)

Specify the distance from the top of the container from which liquid should be aspirated:

AspirationRate  (1)

Specify the flow rate at which a Diluent should be drawn into a pipette tip upon aspiration:

AspirationWithdrawalRate  (1)

Specify the speed at which the pipette is removed from the liquid after an aspiration:

CorrectionCurve  (1)

Specify the relationship between a target volume and the corrected volume that needs to be aspirated or dispensed to reach the target volume:

Diluent  (1)

Specify what diluent in which to resuspend the source sample:

DispenseEquilibrationTime  (1)

Specify the delay length the pipette waits after dispensing before it is removed from the liquid:

DispenseMix  (1)

Indicate that the sample should be mixed after dispensing the Diluent:

DispenseMixRate  (1)

Specify the speed at which liquid is aspirated and dispensed in a liquid after a dispense:

DispenseMixVolume  (1)

Specify the volume of the Diluent that should be aspirated and dispensed quickly to mix after dispensing the source:

DispenseNumberOfMixes  (1)

Specify the number of times the Diluent should be aspirated and dispensed quickly to mix after dispensing the diluent:

DispensePosition  (1)

Specify the location from which liquid should be dispensed:

DispensePositionOffset  (1)

Specify the distance from the top from which liquid should be dispensed:

DispenseRate  (1)

Specify the flow rate at which a Diluent is expelled from the pipette tip as it is dispensed to the sample:

DispenseWithdrawalRate  (1)

Specify the speed at which the pipette is removed from the liquid after a dispense:

DynamicAspiration  (1)

Indicate that the liquid being transferred has a high vapor pressure and droplet prevention should be used:

IncubationInstrument  (1)

Specify if the instrument that performs the mixing/incubating of the sample after diluent is added to the source sample:

IncubationTemperature  (1)

Specify if the temperature at which the sample is mixed/incubated after diluent is added to the source sample:

IncubationTime  (1)

Specify if the length of time the sample is mixed/incubated after diluent is added to the source sample:

MaxIncubationTime  (1)

Specify if the maximum length of time the sample is mixed/incubated until dissolved after diluent is added to the source sample:

MaxNumberOfMixes  (1)

Specify if the maximum number of mixes with which to mix the sample by pipetting or inversion if MixUntilDissolved -> True after diluent is added to the source sample:

MixType  (1)

Specify how the sample should be mixed after diluent is added to the source sample:

MixUntilDissolved  (1)

Specify if the sample should be mixed until it is dissolved after diluent is added to the source sample:

MixVolume  (1)

Specify if the volume with which to mix the sample by pipetting after diluent is added to the source sample:

NumberOfMixes  (1)

Specify if the number of mixes with which to mix the sample by pipetting or inversion after diluent is added to the source sample:

OverAspirationVolume  (1)

Specify the volume of air drawn into the pipette tip at the end of the aspiration of a liquid:

OverDispenseVolume  (1)

Specify the volume of air drawn blown out at the end of the dispensing of a liquid:

PipettingMethod  (1)

Specify a pipetting method object from which pipetting parameters should be used. Any additional specified pipetting parameters will override the object's value:

TipSize  (1)

Specify the tip size to use for transferring the diluent to resuspend the sample:

TipType  (2)

Specify the tip model to use for transferring the diluent to resuspend the sample:

Specify the tip type and size to use:

Volume  (1)

Specify how much Diluent should be used to resuspend the source sample:

Attributes  (1)

Protected  (1)

The Resuspend Head is protected: