ecl-logo Documentation

Model[Instrument, Microscope]

Model of an optical magnification imaging device for obtaining images under bright field or fluorescent illumination.

Organizational Information

    Name

    Name of this Object.
    Format: Single
    Class: String
    Programmatic Pattern: _String
    Pattern Description: A string.

    ID

    ID of this Object.
    Format: Single
    Class: String
    Programmatic Pattern: _String
    Pattern Description: The ID of this object.

    Object

    Object of this Object.
    Format: Single
    Class: Expression
    Programmatic Pattern: Model[Instrument, Microscope, _String]
    Pattern Description: The object reference of this object.

    Type

    Type of this Object.
    Format: Single
    Class: Expression
    Programmatic Pattern: Model[Instrument, Microscope]
    Pattern Description: Model[Instrument, Microscope]

    Notebook

    Notebook this object belongs to.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link
    Pattern Description: An object of that matches ObjectP[Object[LaboratoryNotebook]].

    Objects

    Objects that represent instances of this model.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    Deprecated

    Indicates if this instrument model is historical and no longer used in the lab.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    Authors

    The person(s) who created this instrument model.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link
    Relation: Object[User]

    ImageFile

    An example photo of this model of instrument.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link

    UserManualFiles

    PDFs for the manuals or instruction guides for this model of instrument.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

Instrument Specifications

    InstrumentSchematics

    Detailed drawings of the instrument that explain its capabilities and limitations.
    Format: Multiple

    [[1]] Schematic

    [[2]] Caption

      Header: Caption
      Class: String
      Programmatic Pattern: _String

    PowerType

    The type(s) of the power source(s) used by instruments of this model.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: PowerTypeP

    BatteryRequirements

    All battery requirements for battery-powered instruments of this model.
    Format: Multiple

    [[1]] Number of Batteries

      Header: Number of Batteries
      Class: Integer
      Programmatic Pattern: GreaterP[0, 1]

    [[2]] Battery Type

      Header: Battery Type
      Class: Expression
      Programmatic Pattern: BatteryTypeP

    PowerConsumption

    Estimated power consumption rate of the instrument in Watts (Joule/Second).
    Format: Single
    Class: Real
    Unit: 1 watt
    Programmatic Pattern: GreaterEqualP[0 Watt]

    Connector

    All data connector requirements needed to interface the instruments of this model with a computer.
    Format: Multiple

    [[1]] Number of Connectors

      Header: Number of Connectors
      Class: Integer
      Programmatic Pattern: GreaterP[0, 1]

    [[2]] Connector Type

      Header: Connector Type
      Class: Expression
      Programmatic Pattern: DataConnectorP

    OperatingSystem

    Operating system that the software of instruments of this model runs on.
    Format: Single
    Class: Expression
    Programmatic Pattern: OperatingSystemP

    PCICard

    All PCICard requirements needed to install specialized hardware.
    Format: Multiple

    [[1]] Number of Cards

      Header: Number of Cards
      Class: Integer
      Programmatic Pattern: GreaterEqualP[0, 1]

    [[2]] Card Type

      Header: Card Type
      Class: Expression
      Programmatic Pattern: PCICardP

    Dongle

    Indicates if an instrument of this model requires a security dongle in the computer to run.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    AssociatedAccessories

    Items installed with the instrument for full function.
    Format: Multiple

    [[1]] Item

    [[2]] Quantity

      Header: Quantity
      Class: Integer
      Programmatic Pattern: GreaterP[0, 1]

    WasteType

    The type of waste generated by this instrument.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link
    Relation: Model[Sample]

    Modes

    The types of images the microscope is capable of generating.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: MicroscopeModeP

    HighContentImaging

    Indicates if the instrument is capable of performing high-throughput phenotypic screening of live cells.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    Orientation

    Indicates if the sample is viewed from above (upright) or underneath (inverted).
    Format: Single
    Class: Expression
    Programmatic Pattern: MicroscopeViewOrientationP

    IlluminationTypes

    For each member of Modes, the source of illumination available to image samples on the microscope.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: MicroscopeIlluminationTypeP

    LampTypes

    Indicates the sources of illumination available to the microscope.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: LampTypeP

    CameraModel

    The model of the digital camera connected to the microscope.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link
    Relation: Model[Part]

    Objectives

    For each member of ObjectiveMagnifications, a viewing objective available for this model of microscope.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    OpticModules

    A list of the optic modules, used in fluorescence imaging, available for this model of microscope.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    EyePieceMagnification

    The magnification provided by the eyepiece.
    Format: Single
    Class: Real
    Programmatic Pattern: GreaterP[0]

    ObjectiveMagnifications

    The objective magnifications available for this model of microscope.
    Format: Multiple
    Class: Real
    Programmatic Pattern: GreaterP[0]

    FluorescenceFilters

    The fluorescence filters available, based on the compatible optic modules for this instrument.
    Format: Multiple

    [[1]] Excitation Wavelength

      Header: Excitation Wavelength
      Class: Real
      Unit: 1 nanometer
      Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]

    [[2]] Emission Wavelength

      Header: Emission Wavelength
      Class: Real
      Unit: 1 nanometer
      Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]

    CustomizableImagingChannel

    Indicates if a custom imaging channel can be created from a new combination of available FluorescenceExcitationWavelengths and FluorescenceEmissionWavelengths.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    ImagingChannels

    Indicates the fluorescence imaging channels available for this model of microscope.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: MicroscopeImagingChannelP

    FluorescenceExcitation Wavelengths

    For each member of ImagingChannels, the wavelength that should be used to illuminate the sample.
    Format: Multiple
    Class: Real
    Unit: 1 nanometer
    Programmatic Pattern: GreaterP[0 Nanometer]

    FluorescenceEmission Wavelengths

    For each member of ImagingChannels, the wavelength at which the fluorescence emission of the sample should be imaged.
    Format: Multiple
    Class: Real
    Unit: 1 nanometer
    Programmatic Pattern: GreaterP[0 Nanometer]

    EmissionFilters

    For each member of ImagingChannels, the emission filter available on this instrument model to filter fluorescence emission in a specified wavelength range.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    DichroicFilterWavelengths

    For each member of ImagingChannels, the cutoff wavelength of the dichroic filter that allows longer wavelengths to be transmitted and reflects shorter wavelengths.
    Format: Multiple
    Class: Real
    Unit: 1 nanometer
    Programmatic Pattern: GreaterP[0 Nanometer]

    DichroicFilters

    For each member of ImagingChannels, the dichroic filter available on this instrument model that allows wavelengths above cutoff to be transmitted and reflects shorter wavelengths below cutoff.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    DefaultExcitationPowers

    For each member of ImagingChannels, the default percent of maximum intensity of the light source that should be used to illuminate the sample. Higher percentages indicating higher intensities.
    Format: Multiple
    Class: Real
    Unit: 1 percent
    Programmatic Pattern: RangeP[0 Percent, 100 Percent]

    DefaultTransmittedLightPower

    The default percent of maximum intensity of the white light source that should be used to illuminate the sample. Higher percentages indicating higher intensities.
    Format: Single
    Class: Real
    Unit: 1 percent
    Programmatic Pattern: RangeP[0 Percent, 100 Percent]

    Autofocus

    Indicates if the microscope is fitted with an Autofocus feature to automatically find the focal plane of a sample.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    PixelBinning

    Indicates the combining of "n x n" grid of pixels into a single pixel that is supported by this instrument model. Higher binning values result in higher overall signal-to-noise ratios but lower pixel resolutions.
    Format: Multiple
    Class: Integer
    Programmatic Pattern: GreaterP[0]

    ImageSizeX

    Indicates the size of field of view in X direction (Width) of an unbinned image acquired by this instrument.
    Format: Single
    Class: Real
    Unit: 1 Pixels
    Programmatic Pattern: GreaterP[0 Pixel]

    ImageSizeY

    Indicates the size of field of view in Y direction (Length) of an unbinned image acquired by this instrument.
    Format: Single
    Class: Real
    Unit: 1 Pixels
    Programmatic Pattern: GreaterP[0 Pixel]

    ImageScalesX

    For each member of ObjectiveMagnifications, indicates the size of each pixel in X direction (Width) of an unbinned image acquired by this instrument.
    Format: Multiple
    Class: Real
    Unit: 1 micrometer per Pixels
    Programmatic Pattern: Micrometer Hold[GreaterP[0 ----------]] Pixel

    ImageScalesY

    For each member of ObjectiveMagnifications, indicates the size of each pixel in Y direction (Length) of an unbinned image acquired by this instrument.
    Format: Multiple
    Class: Real
    Unit: 1 micrometer per Pixels
    Programmatic Pattern: Micrometer Hold[GreaterP[0 ----------]] Pixel

    TimelapseImaging

    Indicates if this instrument model can image a sample at multiple time points.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    ZStackImaging

    Indicates if this instrument model can acquire a series of images at multiple z-axis positions from a sample.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    DefaultZStepSizes

    For each member of ObjectiveMagnifications, indicates the recommended distance between images in z-series imaging.
    Format: Multiple
    Class: Real
    Unit: 1 micrometer
    Programmatic Pattern: GreaterP[0 Micrometer]

    ImageCorrectionMethods

    Indicates the correction methods that can be applied to the acquired images by this instrument model. BackgroundCorrection removes stray light that is unrelated to light that reaches the sample. ShadingCorrection mitigates the uneven illumination of the sample that is visible around the edges of the image.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: MicroscopeImageCorrectionP

    DefaultImageCorrections

    For each member of Modes, indicates the default image correction method that should be applied to the acquire image.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: MicroscopeImageCorrectionP

    ImageDeconvolution

    Indicates if this instrument model is fitted with a deconvolution algorithm that can be used to enhance contrast, improve image resolution, and sharpen the image.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    SamplingMethods

    The sampling pattern of images that can be acquired from the samples by this instrument model. SinglePoint: acquires an image at the center of each well or sample. Grid: acquires multiple images along specified rows and columns. Coordinates: acquires image(s) at requested coordinates in each well or on a microscopic slide. Adaptive: uses an algorithm to calculate the number of cells in each field of view to increase the chances of acquiring valid data, until the indicated number of cells specified in AdaptiveNumberOfCells is obtained.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: MicroscopeSamplingMethodP

    DefaultSamplingMethod

    Indicates the default sampling pattern that this instrument model uses to acquire image from a sample.
    Format: Single
    Class: Expression
    Programmatic Pattern: MicroscopeSamplingMethodP

    TransmittedLightColor Correction

    Indicates if the instrument has a neutral color balance filter that can be placed into the transmitted light path to correct the color temperature during BrightField and PhaseContrast imaging.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    TemperatureControlled Environment

    Indicates if the microscope is fitted with a temperature-controlled sample chamber to maintain a specific temperature during imaging.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    IlluminationFilters

    The neutral density filter(s) available on the microscope to used to reduced the intensity of the white illumination light used in bright-field and phase phase-contrast imaging.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    IlluminationColorCorrection Filter

    The neutral color balance Filter(s) available on the microscope used to adjust the color temperature of the image during bright-field and phase-contrast imaging.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    DefaultTargetMaxIntensity

    Indicates the intensity that auto exposure should attempt to attain for the brightest pixel in the image.
    Format: Single
    Class: Integer
    Programmatic Pattern: GreaterP[0]

    MaxGrayLevel

    Indicates the intensity that auto exposure should attempt to attain for the brightest pixel in the image.
    Format: Single
    Class: Integer
    Programmatic Pattern: GreaterP[0]

Pricing Information

    PricingRate

    The rate charged by the ECL for time used on this instrument in the course of conducting user experiments.
    Format: Single
    Class: Real
    Unit: 1 US dollar per hour
    Programmatic Pattern: USD Hold[GreaterEqualP[0 ----]] Hour

    PricingCategory

    The generic billing category this instrument model will be listed under.
    Format: Single
    Class: String
    Programmatic Pattern: PricingCategoryP

    PricingLevel

    With respect to cost, the category of devices, for which this Instrument falls into.
    Format: Single
    Class: Integer
    Programmatic Pattern: GreaterEqualP[0, 1]

Compatibility

    PlugRequirements

    All electrical requirements for plug-in parts of this model.
    Format: Multiple

    [PlugNumber]

      Header: PlugNumber
      Class: Integer

    [Phases]

      Header: Phases
      Class: Integer

    [Voltage]

      Header: Voltage
      Class: Integer
      Unit: 1 volt

    [Current]

      Header: Current
      Class: Real
      Unit: 1 ampere

    [PlugType]

      Header: PlugType
      Class: String

    AllowedPositions

    Generates a pattern of all the valid position names for this model of instrument.
    Format: Computable
    Programmatic Pattern: _Alternatives
    Expression: SafeEvaluate[{Field[Positions]}, Computables`Private`allowedPositions[Field[Positions]]]

    WettedMaterials

    A list of materials in the instrument which may be wetted by user-specified liquids.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: MaterialP

    FacilityRequirementFiles

    PDFs for facility requirements and pre-installation checkoff forms provided by the supplier for instruments of this model.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

Dimensions & Positions

    Dimensions

    The external dimensions of this model of instrument.
    Format: Single

    [[1]] DimensionX

      Header: DimensionX
      Class: Real
      Unit: 1 meter
      Programmatic Pattern: GreaterP[0 Meter]

    [[2]] DimensionY

      Header: DimensionY
      Class: Real
      Unit: 1 meter
      Programmatic Pattern: GreaterP[0 Meter]

    [[3]] DimensionZ

      Header: DimensionZ
      Class: Real
      Unit: 1 meter
      Programmatic Pattern: GreaterP[0 Meter]

    CrossSectionalShape

    The shape of this model of instrument in the X-Y plane.
    Format: Single
    Class: Expression
    Programmatic Pattern: Circle | Rectangle

    ContainerImage2DFile

    A top-down (X-Y plane) image of this model of instrument which can be overlaid on a 2D container plot.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link

    Shape2D

    A Graphics primitive corresponding to the 2D shape of this model of instrument.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Polygon | _Circle

    Shape3D

    A Graphics primitive corresponding to the 3D shape of this model of instrument.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Polygon

    Positions

    Spatial definitions of the positions that exist in this model of instrument.
    Format: Multiple

    [Name]

      Header: Name
      Class: String

    [Footprint]

      Header: Footprint
      Class: Expression

    [MaxWidth]

      Header: MaxWidth
      Class: Real
      Unit: 1 meter

    [MaxDepth]

      Header: MaxDepth
      Class: Real
      Unit: 1 meter

    [MaxHeight]

      Header: MaxHeight
      Class: Real
      Unit: 1 meter

    AvailableLayouts

    Readily available configurations of container models in specified positions on the deck of this instrument model.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

Storage Information

    LocalCacheContents

    Items required to be present in the local cache for instruments of this model, along with the required quantity of each item.
    Format: Multiple

    [[1]] Item Model

    [[2]] Required Quantity

      Header: Required Quantity
      Class: Integer
      Programmatic Pattern: GreaterEqualP[0, 1]

    ProvidedStorageCondition

    The physical conditions such as temperature and humidity this instrument provides for samples stored long term within it.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link

Plumbing Information

    Connectors

    Specifications for the ports on this model of instrument that may connect to other plumbing components.
    Format: Multiple

    [[1]] Connector Name

      Header: Connector Name
      Class: String
      Programmatic Pattern: ConnectorNameP

    [[2]] Connector Type

      Header: Connector Type
      Class: Expression
      Programmatic Pattern: ConnectorP

    [[3]] Thread Type

      Header: Thread Type
      Class: Expression
      Programmatic Pattern: ThreadP|GroundGlassJointSizeP|None

    [[4]] Inner Diameter

      Header: Inner Diameter
      Class: Real
      Unit: 1 inch
      Programmatic Pattern: GreaterP[0 Inch]

    [[5]] Outer Diameter

      Header: Outer Diameter
      Class: Real
      Unit: 1 inch
      Programmatic Pattern: GreaterP[0 Inch]

    [[6]] Gender

      Header: Gender
      Class: Expression
      Programmatic Pattern: ConnectorGenderP|None

Wiring Information

    WiringConnectors

    Specifications for the wiring ends of this instrument that may plug into and conductively connect to other items, parts or instruments.
    Format: Multiple

    [[1]] Wiring Connector Name

      Header: Wiring Connector Name
      Class: String
      Programmatic Pattern: WiringConnectorNameP

    [[2]] Wiring Connector Type

      Header: Wiring Connector Type
      Class: Expression
      Programmatic Pattern: WiringConnectorP

    [[3]] Gender

      Header: Gender
      Class: Expression
      Programmatic Pattern: ConnectorGenderP|None

Qualifications & Maintenance

    QualificationFrequency

    A list of the Qualifications which should be run on instruments of this model and their required frequencies.
    Format: Multiple

    [[1]] Qualification Model

    [[2]] Time

      Header: Time
      Class: Real
      Unit: 1 day
      Programmatic Pattern: GreaterP[0 Second]

    MaintenanceFrequency

    A list of the maintenance protocols which should be run on instruments of this model and their required frequencies.
    Format: Multiple

    [[1]] Maintenance Model

    [[2]] Time

      Header: Time
      Class: Real
      Unit: 1 day
      Programmatic Pattern: GreaterP[0 Second]

    ReplacementParts

    A list of tracked replacement part models for this instrument.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    PassiveClean

    Indicates if the exterior surfaces of this instrument model can be cleaned while in use.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    VentilationFlowRate Requirement

    The minimum flow rate of air generated by the instrument's ventilator for its safe and proper function.
    Format: Single
    Class: Real
    Unit: 1 meter per second
    Programmatic Pattern: Meter Hold[GreaterP[0 ------]] Second

    VentilationFlowRate Recommendation

    The flow rate of air generated by the instrument's ventilator recommended by its manufacturer.
    Format: Single
    Class: Real
    Unit: 1 meter per second
    Programmatic Pattern: Meter Hold[GreaterP[0 ------]] Second

    ContinuousOperation

    Indicates if the instrument is required to operate continuously in the lab, regardless of if it is InUse by a specific protocol, such as a freezer.
    Format: Single
    Class: Boolean
    Programmatic Pattern: BooleanP

    MicroscopeCalibration

    Indicates if the microscope can be calibrated by running a maintenance protocol.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

Inventory

Health & Safety

    Sterile

    Indicates that this model of instrument is used for protocols where SterileTechnique is indicated to be used.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    CultureHandling

    Indicates the type of cellular samples (Mammalian or Microbial) that this instrument is used to handle.
    Format: Single
    Class: Expression
    Programmatic Pattern: CellTypeP

    GloveBoxStorage

    Indiciates that this model of instrument permanently resides in the glove box.
    Format: Single
    Class: Boolean
    Programmatic Pattern: BooleanP

    HazardCategories

    Hazards to be aware of during operation of instruments of this model.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: HazardCategoryP

    SampleHandlingCategories

    Special handling considerations that samples on this instrument require.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: HandlingCategoryP

Sensor Information

    SensorBarrier

    Type of sensors which cannot monitor the internal contents of instruments of this model from the outside.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: TypeP[Object[Sensor]]

Operating Limits

    MaxImagingChannels

    Maximum number of imaging channels allowed per each imaging run.
    Format: Single
    Class: Integer
    Programmatic Pattern: GreaterP[0]

    MinZStepSize

    Indicates the minimum distance between images in z-series imaging.
    Format: Single
    Class: Real
    Unit: 1 micrometer
    Programmatic Pattern: GreaterP[0 Micrometer]

    MaxZStepSize

    Indicates the maximum distance between images in z-series imaging.
    Format: Single
    Class: Real
    Unit: 1 micrometer
    Programmatic Pattern: GreaterP[0 Micrometer]

    MinNumberOfZSteps

    Indicates the minimum distance between images in z-series imaging.
    Format: Single
    Class: Integer
    Unit: 1 micrometer
    Programmatic Pattern: GreaterP[0]

    MaxFocalHeight

    Indicates the maximum distance that the imaging stage can move vertically to bring sample into focus.
    Format: Single
    Class: Real
    Unit: 1 micrometer
    Programmatic Pattern: GreaterP[0 Micrometer]

    MinTemperatureControl

    Minimum temperature at which this instrument model can perform thermal incubation while imaging.
    Format: Single
    Class: Real
    Unit: 1 degree Celsius
    Programmatic Pattern: GreaterP[0 Celsius]

    MaxTemperatureControl

    Maximum temperature at which this instrument model can perform thermal incubation while imaging.
    Format: Single
    Class: Real
    Unit: 1 degree Celsius
    Programmatic Pattern: GreaterP[0 Celsius]

    CarbonDioxideControl

    Indicates if the microscope is fitted with a carbon dioxide-controlled sample chamber to maintain a specified carbon dioxide percentage while imaging.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    HumidityControl

    Indicates if the microscope is fitted with a chamber that maintains humidity to prevent evaporation while imaging.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    ActiveHumidityControl

    Indicates if the microscope is fitted with a chamber that can maintain humidity at a specified percentage (or alternatively if the humidity is dependent on the temperature) while imaging.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    CondenserMinHeight

    The minimum height, measured from the stage to the condenser bottom, that the condenser mount can be adjusted to.
    Format: Single
    Class: Real
    Unit: 1 millimeter
    Programmatic Pattern: GreaterP[0 Millimeter]

    CondenserMaxHeight

    The maximum height, measured from the stage to the condenser bottom, that the condenser mount can be adjusted to.
    Format: Single
    Class: Real
    Unit: 1 millimeter
    Programmatic Pattern: GreaterP[0 Millimeter]

    MinExposureTime

    The minimum amount of time for which a camera shutter can stay open when acquiring an image.
    Format: Single
    Class: Real
    Unit: 1 millisecond
    Programmatic Pattern: GreaterP[0 Millisecond]

    MaxExposureTime

    The maximum amount of time for which a camera shutter can stay open when acquiring an image.
    Format: Single
    Class: Real
    Unit: 1 millisecond
    Programmatic Pattern: GreaterP[0 Millisecond]
Last modified on Mon 26 Sep 2022 15:43:54