Model[Instrument, PlateReader]
The model for an instrument used to read fluorescence, AlphaScreen, absorbance, or luminescence data from well-plates.
Organizational Information
Name
Name of this Object.
Format: Single
Class: String
Programmatic Pattern: _String
Pattern Description: A string.
ID
ID of this Object.
Format: Single
Class: String
Programmatic Pattern: _String
Pattern Description: The ID of this object.
Object
Object of this Object.
Format: Single
Class: Expression
Programmatic Pattern: Model[Instrument, PlateReader, _String]
Pattern Description: The object reference of this object.
Type
Type of this Object.
Format: Single
Class: Expression
Programmatic Pattern: Model[Instrument, PlateReader]
Pattern Description: Model[Instrument, PlateReader]
Notebook
Notebook this object belongs to.
Format: Single
Class: Link
Programmatic Pattern: _Link
Pattern Description: An object of that matches ObjectP[Object[LaboratoryNotebook]].
Relation: Object[LaboratoryNotebook][Objects]
Objects
Objects that represent instances of this model.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Instrument, PlateReader][Model]
Deprecated
Indicates if this instrument model is historical and no longer used in the lab.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
Authors
The person(s) who created this instrument model.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[User]
ImageFile
An example photo of this model of instrument.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
UserManualFiles
PDFs for the manuals or instruction guides for this model of instrument.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
Instrument Specifications
InstrumentSchematics
Detailed drawings of the instrument that explain its capabilities and limitations.
Format: Multiple
[[1]] Schematic
Header: Schematic
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
[[2]] Caption
Header: Caption
Class: String
Programmatic Pattern: _String
PowerType
The type(s) of the power source(s) used by instruments of this model.
Format: Multiple
Class: Expression
Programmatic Pattern: PowerTypeP
BatteryRequirements
All battery requirements for battery-powered instruments of this model.
Format: Multiple
[[1]] Number of Batteries
Header: Number of Batteries
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
[[2]] Battery Type
Header: Battery Type
Class: Expression
Programmatic Pattern: BatteryTypeP
PowerConsumption
Estimated power consumption rate of the instrument in Watts (Joule/Second).
Format: Single
Class: Real
Unit: 1 watt
Programmatic Pattern: GreaterEqualP[0 Watt]
Connector
All data connector requirements needed to interface the instruments of this model with a computer.
Format: Multiple
[[1]] Number of Connectors
Header: Number of Connectors
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
[[2]] Connector Type
Header: Connector Type
Class: Expression
Programmatic Pattern: DataConnectorP
OperatingSystem
Operating system that the software of instruments of this model runs on.
Format: Single
Class: Expression
Programmatic Pattern: OperatingSystemP
PCICard
All PCICard requirements needed to install specialized hardware.
Format: Multiple
[[1]] Number of Cards
Header: Number of Cards
Class: Integer
Programmatic Pattern: GreaterEqualP[0, 1]
[[2]] Card Type
Header: Card Type
Class: Expression
Programmatic Pattern: PCICardP
Dongle
Indicates if an instrument of this model requires a security dongle in the computer to run.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
AssociatedAccessories
Items installed with the instrument for full function.
Format: Multiple
[[1]] Item
Header: Item
Class: Link
Programmatic Pattern: _Link
Relation: Model[Instrument][SupportedInstruments] | Model[Part][SupportedInstruments] | Model[Container, PlateSealMagazine][SupportedInstruments] | Model[Container, MagazineParkPosition][SupportedInstruments] | Model[Sensor][SupportedInstruments] | Model[Item][SupportedInstruments] | Model[Plumbing][SupportedInstruments] | Model[Wiring][SupportedInstruments]
[[2]] Quantity
Header: Quantity
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
WasteType
The type of waste generated by this instrument.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Model[Sample]
PlateReaderMode
The type of data that can be collected by the plate reader.
Format: Multiple
Class: Expression
Programmatic Pattern: PlateReaderModeP
AbsorbanceDetector
The type of detector available to measure the absorbance.
Format: Single
Class: Expression
Programmatic Pattern: OpticalDetectorP
AbsorbanceFilterTypes
The types of wavelength selection available for absorbance measurement.
Format: Multiple
Class: Expression
Programmatic Pattern: PlateReaderWavelengthSelectionTypeP
ExcitationSource
The light sources available to excite and probe the sample.
Format: Multiple
Class: Expression
Programmatic Pattern: ExcitationSourceP
ExcitationFilterTypes
The types of wavelength selection available for the excitation.
Format: Multiple
Class: Expression
Programmatic Pattern: PlateReaderWavelengthSelectionTypeP
EmissionFilterTypes
The types of wavelength selection available for the emission paths.
Format: Multiple
Class: Expression
Programmatic Pattern: PlateReaderWavelengthSelectionTypeP
EmissionDetector
The type of detector available to measure the emissions from the sample.
Format: Single
Class: Expression
Programmatic Pattern: OpticalDetectorP
LuminescenceDetector
The type of wavelength selection available for luminescence measurement.
Format: Single
Class: Expression
Programmatic Pattern: {OpticalDetectorP..}
LuminescenceFilterTypes
The types of wavelength selection available for luminescence measurement.
Format: Multiple
Class: Expression
Programmatic Pattern: PlateReaderWavelengthSelectionTypeP
PolarizationExcitationSource
The light source available to excite and probe the sample with polarized light.
Format: Multiple
Class: Expression
Programmatic Pattern: ExcitationSourceP
ExcitationPolarizers
List of the possible optical polarizations to use on the excitation source for polarized light.
Format: Multiple
Class: Expression
Programmatic Pattern: OpticalPolarizationP
PolarizationExcitationFilter Types
The type of wavelength selection available for the excitation.
Format: Multiple
Class: Expression
Programmatic Pattern: PlateReaderWavelengthSelectionTypeP
PolarizationEmissionFilter Types
The types of wavelength selection available for the emission paths.
Format: Multiple
Class: Expression
Programmatic Pattern: PlateReaderWavelengthSelectionTypeP
EmissionPolarizers
List of the possible optical polarizations to use on the emission path source for polarized light.
Format: Multiple
[[1]] Primary Emission Polarization
Header: Primary Emission Polarization
Class: Expression
Programmatic Pattern: OpticalPolarizationP
[[2]] Secondary Emission Polarization
Header: Secondary Emission Polarization
Class: Expression
Programmatic Pattern: OpticalPolarizationP
PolarizationEmissionDetector
The type of detector available to measure the light after the polarization and emission filters.
Format: Single
Class: Expression
Programmatic Pattern: OpticalDetectorP
OpticModules
A list of optic modules compatible with this model of plate reader.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Model[Part]
SamplingPatterns
Indicates the type of sampling each plate reader mode can perform.
Format: Single
[AbsorbanceIntensity]
Header: AbsorbanceIntensity
Class: Expression
[AbsorbanceKinetics]
Header: AbsorbanceKinetics
Class: Expression
[AbsorbanceSpectroscopy]
Header: AbsorbanceSpectroscopy
Class: Expression
[FluorescenceIntensity]
Header: FluorescenceIntensity
Class: Expression
[FluorescenceKinetics]
Header: FluorescenceKinetics
Class: Expression
[FluorescenceSpectroscopy]
Header: FluorescenceSpectroscopy
Class: Expression
[FluorescencePolarization]
Header: FluorescencePolarization
Class: Expression
[FluorescencePolarizationKinetics]
Header: FluorescencePolarizationKinetics
Class: Expression
[TimeResolvedFluorescence]
Header: TimeResolvedFluorescence
Class: Expression
[TimeResolvedFluorescenceKinetics]
Header: TimeResolvedFluorescenceKinetics
Class: Expression
[LuminescenceIntensity]
Header: LuminescenceIntensity
Class: Expression
[LuminescenceKinetics]
Header: LuminescenceKinetics
Class: Expression
[LuminescenceSpectroscopy]
Header: LuminescenceSpectroscopy
Class: Expression
AvailableGases
The gases whose levels can be controlled in the atmosphere inside the plate reader.
Format: Multiple
Class: Expression
Programmatic Pattern: CarbonDioxide | Oxygen
Pricing Information
PricingRate
The rate charged by the ECL for time used on this instrument in the course of conducting user experiments.
Format: Single
Class: Real
Unit: 1 US dollar per hour
Programmatic Pattern: USD
Hold[GreaterEqualP[0 ----]]
Hour
PricingCategory
The generic billing category this instrument model will be listed under.
Format: Single
Class: String
Programmatic Pattern: PricingCategoryP
PricingLevel
With respect to cost, the category of devices, for which this Instrument falls into.
Format: Single
Class: Integer
Programmatic Pattern: GreaterEqualP[0, 1]
Compatibility
PlugRequirements
All electrical requirements for plug-in parts of this model.
Format: Multiple
[PlugNumber]
Header: PlugNumber
Class: Integer
[Phases]
Header: Phases
Class: Integer
[Voltage]
Header: Voltage
Class: Integer
Unit: 1 volt
[Current]
Header: Current
Class: Real
Unit: 1 ampere
[PlugType]
Header: PlugType
Class: String
AllowedPositions
Generates a pattern of all the valid position names for this model of instrument.
Format: Computable
Programmatic Pattern: _Alternatives
Expression: SafeEvaluate[{Field[Positions]}, Computables`Private`allowedPositions[Field[Positions]]]
WettedMaterials
A list of materials in the instrument which may be wetted by user-specified liquids.
Format: Multiple
Class: Expression
Programmatic Pattern: MaterialP
FacilityRequirementFiles
PDFs for facility requirements and pre-installation checkoff forms provided by the supplier for instruments of this model.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
CompatiblePlates
Plates that can be placed on the measurement tray of this model of instrument.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Model[Container]
Dimensions & Positions
Dimensions
The external dimensions of this model of instrument.
Format: Single
[[1]] DimensionX
Header: DimensionX
Class: Real
Unit: 1 meter
Programmatic Pattern: GreaterP[0 Meter]
[[2]] DimensionY
Header: DimensionY
Class: Real
Unit: 1 meter
Programmatic Pattern: GreaterP[0 Meter]
[[3]] DimensionZ
Header: DimensionZ
Class: Real
Unit: 1 meter
Programmatic Pattern: GreaterP[0 Meter]
CrossSectionalShape
The shape of this model of instrument in the X-Y plane.
Format: Single
Class: Expression
Programmatic Pattern: Circle | Rectangle
ContainerImage2DFile
A top-down (X-Y plane) image of this model of instrument which can be overlaid on a 2D container plot.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
Shape2D
A Graphics primitive corresponding to the 2D shape of this model of instrument.
Format: Single
Class: Expression
Programmatic Pattern: _Polygon | _Circle
Shape3D
A Graphics primitive corresponding to the 3D shape of this model of instrument.
Format: Single
Class: Expression
Programmatic Pattern: _Polygon
Positions
Spatial definitions of the positions that exist in this model of instrument.
Format: Multiple
[Name]
Header: Name
Class: String
[Footprint]
Header: Footprint
Class: Expression
[MaxWidth]
Header: MaxWidth
Class: Real
Unit: 1 meter
[MaxDepth]
Header: MaxDepth
Class: Real
Unit: 1 meter
[MaxHeight]
Header: MaxHeight
Class: Real
Unit: 1 meter
AvailableLayouts
Readily available configurations of container models in specified positions on the deck of this instrument model.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Model[DeckLayout][InstrumentModel]
Storage Information
LocalCacheContents
Items required to be present in the local cache for instruments of this model, along with the required quantity of each item.
Format: Multiple
[[1]] Item Model
Header: Item Model
Class: Link
Programmatic Pattern: _Link
[[2]] Required Quantity
Header: Required Quantity
Class: Integer
Programmatic Pattern: GreaterEqualP[0, 1]
ProvidedStorageCondition
The physical conditions such as temperature and humidity this instrument provides for samples stored long term within it.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Model[StorageCondition]
Plumbing Information
Connectors
Specifications for the ports on this model of instrument that may connect to other plumbing components.
Format: Multiple
[[1]] Connector Name
Header: Connector Name
Class: String
Programmatic Pattern: ConnectorNameP
[[2]] Connector Type
Header: Connector Type
Class: Expression
Programmatic Pattern: ConnectorP
[[3]] Thread Type
Header: Thread Type
Class: Expression
Programmatic Pattern: ThreadP|GroundGlassJointSizeP|None
[[4]] Inner Diameter
Header: Inner Diameter
Class: Real
Unit: 1 inch
Programmatic Pattern: GreaterP[0 Inch]
[[5]] Outer Diameter
Header: Outer Diameter
Class: Real
Unit: 1 inch
Programmatic Pattern: GreaterP[0 Inch]
[[6]] Gender
Header: Gender
Class: Expression
Programmatic Pattern: ConnectorGenderP|None
Wiring Information
WiringConnectors
Specifications for the wiring ends of this instrument that may plug into and conductively connect to other items, parts or instruments.
Format: Multiple
[[1]] Wiring Connector Name
Header: Wiring Connector Name
Class: String
Programmatic Pattern: WiringConnectorNameP
[[2]] Wiring Connector Type
Header: Wiring Connector Type
Class: Expression
Programmatic Pattern: WiringConnectorP
[[3]] Gender
Header: Gender
Class: Expression
Programmatic Pattern: ConnectorGenderP|None
Qualifications & Maintenance
QualificationFrequency
A list of the Qualifications which should be run on instruments of this model and their required frequencies.
Format: Multiple
[[1]] Qualification Model
Header: Qualification Model
Class: Link
Programmatic Pattern: _Link
Relation: Model[Qualification][Targets]
[[2]] Time
Header: Time
Class: Real
Unit: 1 day
Programmatic Pattern: GreaterP[0 Second]
MaintenanceFrequency
A list of the maintenance protocols which should be run on instruments of this model and their required frequencies.
Format: Multiple
[[1]] Maintenance Model
Header: Maintenance Model
Class: Link
Programmatic Pattern: _Link
Relation: Model[Maintenance][Targets]
[[2]] Time
Header: Time
Class: Real
Unit: 1 day
Programmatic Pattern: GreaterP[0 Second]
ReplacementParts
A list of tracked replacement part models for this instrument.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
PassiveClean
Indicates if the exterior surfaces of this instrument model can be cleaned while in use.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
VentilationFlowRate Requirement
The minimum flow rate of air generated by the instrument's ventilator for its safe and proper function.
Format: Single
Class: Real
Unit: 1 meter per second
Programmatic Pattern: Meter
Hold[GreaterP[0 ------]]
Second
VentilationFlowRate Recommendation
The flow rate of air generated by the instrument's ventilator recommended by its manufacturer.
Format: Single
Class: Real
Unit: 1 meter per second
Programmatic Pattern: Meter
Hold[GreaterP[0 ------]]
Second
ContinuousOperation
Indicates if the instrument is required to operate continuously in the lab, regardless of if it is InUse by a specific protocol, such as a freezer.
Format: Single
Class: Boolean
Programmatic Pattern: BooleanP
Inventory
Manufacturer
The company that originally manufactured this model of instrument.
Format: Single
Class: Link
Programmatic Pattern: _Link
SupportedInstruments
A list of instruments for which this model is an accompanying accessory.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Health & Safety
Sterile
Indicates that this model of instrument is used for protocols where SterileTechnique is indicated to be used.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
CultureHandling
Indicates the type of cellular samples (Mammalian or Microbial) that this instrument is used to handle.
Format: Single
Class: Expression
Programmatic Pattern: CellTypeP
GloveBoxStorage
Indiciates that this model of instrument permanently resides in the glove box.
Format: Single
Class: Boolean
Programmatic Pattern: BooleanP
HazardCategories
Hazards to be aware of during operation of instruments of this model.
Format: Multiple
Class: Expression
Programmatic Pattern: HazardCategoryP
SampleHandlingCategories
Special handling considerations that samples on this instrument require.
Format: Multiple
Class: Expression
Programmatic Pattern: HandlingCategoryP
Sensor Information
SensorBarrier
Type of sensors which cannot monitor the internal contents of instruments of this model from the outside.
Format: Multiple
Class: Expression
Programmatic Pattern: TypeP[Object[Sensor]]
Operating Limits
MinOxygenLevel
Minimum level of oxygen in the atmosphere inside the plate reader that can be maintained.
Format: Single
Class: Real
Unit: 1 percent
Programmatic Pattern: GreaterP[0 Percent]
MaxOxygenLevel
Maximum level of oxygen in the atmosphere inside the plate reader that can be maintained.
Format: Single
Class: Real
Unit: 1 percent
Programmatic Pattern: GreaterP[0 Percent]
MinCarbonDioxideLevel
Minimum level of carbon dioxide in the atmosphere inside the plate reader that can be maintained.
Format: Single
Class: Real
Unit: 1 percent
Programmatic Pattern: GreaterP[0 Percent]
MaxCarbonDioxideLevel
Maximum level of carbon dioxide in the atmosphere inside the plate reader that can be maintained.
Format: Single
Class: Real
Unit: 1 percent
Programmatic Pattern: GreaterP[0 Percent]
MinTemperature
Minimum temperature at which the plate reader can incubate.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterP[0 Kelvin]
MaxTemperature
Maximum temperature at which the plate reader can incubate.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterP[0 Kelvin]
InjectorVolume
The volume of the injector used to add liquid to the plate.
Format: Single
Class: Real
Unit: 1 liter
Programmatic Pattern: GreaterEqualP[0 Liter]
InjectorDeadVolume
The volume of the tube between the injector syringe and the injector nozzle. This volume is required to fill the injector tube and cannot be injected into wells.
Format: Single
Class: Real
Unit: 1 liter
Programmatic Pattern: GreaterEqualP[0 Liter]
MaxDispensingSpeed
Maximum speed reagent can be delivered to the read wells.
Format: Single
Class: Real
Unit: 1 milliliter per minute
Programmatic Pattern: 0 (Liter Milli)
Hold[GreaterP[---------------]]
Minute
MinAbsorbanceWavelength
The minimum wavelength at which the instrument can take absorbance readings.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
MaxAbsorbanceWavelength
The maximum wavelength at which the instrument can take absorbance readings.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
AbsorbanceWavelength Resolution
The resolution available in selecting the absorbance wavelength to measure.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
LinearAbsorbanceRange
The reliable linear 10 mm-equivalent absorbance range of this model of instrument.
Format: Single
[[1]] MinAbsorbance
Header: MinAbsorbance
Class: Real
Unit: 1 AbsorbanceUnit
Programmatic Pattern: GreaterEqualP[0 AbsorbanceUnit]
[[2]] MaxAbsorbance
Header: MaxAbsorbance
Class: Real
Unit: 1 AbsorbanceUnit
Programmatic Pattern: GreaterEqualP[0 AbsorbanceUnit]
MinExcitationWavelength
The minimum wavelength at which the instrument can excite the sample.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
MaxExcitationWavelength
The maximum wavelength at which the instrument can excite the sample.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
ExcitationFilters
List of the possible optical filters to use on the excitation source. Output is in the form: {wavelength,..}.
Format: Multiple
Class: Expression
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
ExcitationWavelength Resolution
The resolution available in selecting the excitation wavelength, if is tunable.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
MinEmissionWavelength
The minimum wavelength at which the instrument can take emission readings.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
MaxEmissionWavelength
The maximum wavelength at which the instrument can take emission readings.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
EmissionFilters
List of the possible optical filters to use on the emission path. Output is in the form: {primary emission wavelength,secondary emission wavelength}.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterP[0 Nano Meter, 1 Nano Meter], GreaterP[0 Nano Meter, 1 Nano Meter] | Null}
EmissionWavelengthResolution
The resolution available in selecting the emission wavelength to measure.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
AlphaScreenExcitationLaser Wavelength
The laser used as the excitation source for AlphaScreen.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nanometer]
AlphaScreenEmissionFilter
The optical filter used on the emission path for AlphaScreen.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nanometer]
MinLuminescenceWavelength
The minimum wavelength at which the instrument can take luminescence readings.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
MaxLuminescenceWavelength
The maximum wavelength at which the instrument can take luminescence readings.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
PolarizationExcitationFilters
List of the possible optical filters to use on the excitation source for polarized light. Output is in the form: {wavelength,..}.
Format: Multiple
Class: Expression
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
PolarizationEmissionFilters
List of the possible optical filters to use on the polarized light path. Output is in the form: {primary polarized emission wavelength,secondary polarized emission wavelength}.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterP[0 Nano Meter, 1 Nano Meter], GreaterP[0 Nano Meter, 1 Nano Meter] | Null}
MinPolarizationEmission Wavelength
The minimum wavelength at which the instrument can take polarized light readings.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
MaxPolarizationEmission Wavelength
The maximum wavelength at which the instrument can take polarized light readings.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
MaxOpticModules
The maximum number of optic modules that can be installed in this model of instrument.
Format: Single
Class: Integer
Programmatic Pattern: GreaterEqualP[0, 1]
MaxFilters
The maximum number of fluorescence filters that can be installed in this model of instrument.
Format: Single
Class: Integer
Programmatic Pattern: GreaterEqualP[0, 1]
MinAbsorbance
The minimum 10 mm-equivalent absorbance that this model instrument can read within a manufacturer reported linear range.
Format: Single
Class: Real
Unit: 1 AbsorbanceUnit
Programmatic Pattern: GreaterEqualP[0]
MaxAbsorbance
The maximum 10 mm-equivalent absorbance that this model instrument can read within a manufacturer reported linear range.
Format: Single
Class: Real
Unit: 1 AbsorbanceUnit
Programmatic Pattern: GreaterEqualP[0]
MaxFluorescence
The maximum relative fluorescence value which this instrument is detector capable of recording (any signal stronger then this simply maxes out by recording this value).
Format: Single
Class: Real
Unit: 1 Rfus
Programmatic Pattern: GreaterP[0 RFU]
Last modified on Mon 26 Sep 2022 15:43:54