Model[Instrument, FPLC]
The model for a fast protein liquid chromatography instrument that is used to analyze or purify mixtures of biomolecules.
Organizational Information
Name
Name of this Object.
Format: Single
Class: String
Programmatic Pattern: _String
Pattern Description: A string.
ID
ID of this Object.
Format: Single
Class: String
Programmatic Pattern: _String
Pattern Description: The ID of this object.
Object
Object of this Object.
Format: Single
Class: Expression
Programmatic Pattern: Model[Instrument, FPLC, _String]
Pattern Description: The object reference of this object.
Type
Type of this Object.
Format: Single
Class: Expression
Programmatic Pattern: Model[Instrument, FPLC]
Pattern Description: Model[Instrument, FPLC]
Notebook
Notebook this object belongs to.
Format: Single
Class: Link
Programmatic Pattern: _Link
Pattern Description: An object of that matches ObjectP[Object[LaboratoryNotebook]].
Relation: Object[LaboratoryNotebook][Objects]
Objects
Objects that represent instances of this model.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Instrument, FPLC][Model]
Deprecated
Indicates if this instrument model is historical and no longer used in the lab.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
Authors
The person(s) who created this instrument model.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[User]
ImageFile
An example photo of this model of instrument.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
UserManualFiles
PDFs for the manuals or instruction guides for this model of instrument.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
Instrument Specifications
InstrumentSchematics
Detailed drawings of the instrument that explain its capabilities and limitations.
Format: Multiple
[[1]] Schematic
Header: Schematic
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
[[2]] Caption
Header: Caption
Class: String
Programmatic Pattern: _String
PowerType
The type(s) of the power source(s) used by instruments of this model.
Format: Multiple
Class: Expression
Programmatic Pattern: PowerTypeP
BatteryRequirements
All battery requirements for battery-powered instruments of this model.
Format: Multiple
[[1]] Number of Batteries
Header: Number of Batteries
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
[[2]] Battery Type
Header: Battery Type
Class: Expression
Programmatic Pattern: BatteryTypeP
PowerConsumption
Estimated power consumption rate of the instrument in Watts (Joule/Second).
Format: Single
Class: Real
Unit: 1 watt
Programmatic Pattern: GreaterEqualP[0 Watt]
Connector
All data connector requirements needed to interface the instruments of this model with a computer.
Format: Multiple
[[1]] Number of Connectors
Header: Number of Connectors
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
[[2]] Connector Type
Header: Connector Type
Class: Expression
Programmatic Pattern: DataConnectorP
OperatingSystem
Operating system that the software of instruments of this model runs on.
Format: Single
Class: Expression
Programmatic Pattern: OperatingSystemP
PCICard
All PCICard requirements needed to install specialized hardware.
Format: Multiple
[[1]] Number of Cards
Header: Number of Cards
Class: Integer
Programmatic Pattern: GreaterEqualP[0, 1]
[[2]] Card Type
Header: Card Type
Class: Expression
Programmatic Pattern: PCICardP
Dongle
Indicates if an instrument of this model requires a security dongle in the computer to run.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
AssociatedAccessories
Items installed with the instrument for full function.
Format: Multiple
[[1]] Item
Header: Item
Class: Link
Programmatic Pattern: _Link
Relation: Model[Instrument][SupportedInstruments] | Model[Part][SupportedInstruments] | Model[Container, PlateSealMagazine][SupportedInstruments] | Model[Container, MagazineParkPosition][SupportedInstruments] | Model[Sensor][SupportedInstruments] | Model[Item][SupportedInstruments] | Model[Plumbing][SupportedInstruments] | Model[Wiring][SupportedInstruments]
[[2]] Quantity
Header: Quantity
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
WasteType
The type of waste generated by this instrument.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Model[Sample]
Detectors
A list of the available chromatographic detectors on the instrument.
Format: Multiple
Class: Expression
Programmatic Pattern: ChromatographyDetectorTypeP
DetectorLampType
A list of sources of illumination available for use in detection.
Format: Multiple
Class: Expression
Programmatic Pattern: LampTypeP
AbsorbanceDetector
The type of detector available to measure the absorbance.
Format: Single
Class: Expression
Programmatic Pattern: OpticalDetectorP
AbsorbanceFilterType
The type of wavelength selection available for absorbance measurement.
Format: Single
Class: Expression
Programmatic Pattern: WavelengthSelectionTypeP
AutosamplerTubingDeadVolume
The total volume of the tubes that connect the ends of the sample loop in the autosampler to the injection valve of the FPLC instrument.
Format: Single
Class: Real
Unit: 1 milliliter
Programmatic Pattern: GreaterEqualP[0 Milliliter]
Mixer
The type of mixer the pump uses to generate the gradient.
Format: Single
Class: Expression
Programmatic Pattern: ChromatographyMixerTypeP
SampleLoop
The maximum volume of sample that should be loaded in the injection loop, before it is transferred into the flow path.
Format: Single
Class: Real
Unit: 1 microliter
Programmatic Pattern: GreaterEqualP[0 Micro Liter]
DelayVolume
The tubing volume between the detector and the fraction collector head.
Format: Single
Class: Real
Unit: 1 microliter
Programmatic Pattern: GreaterEqualP[0 Micro Liter]
DelayLength
The length of tubing between the detector and the fraction collector.
Format: Single
Class: Real
Unit: 1 centimeter
Programmatic Pattern: GreaterEqualP[0 Centi Meter]
FlowCellVolume
The volume of the instrument's detector's flow cell.
Format: Single
Class: Real
Unit: 1 microliter
Programmatic Pattern: GreaterEqualP[0 Micro Liter]
FlowCellPathLength
The pathlength of instrument's detector's flow cell.
Format: Single
Class: Real
Unit: 1 millimeter
Programmatic Pattern: GreaterEqualP[0 Milli Meter]
TubingInnerDiameter
The diameter of the tubing in the flow path.
Format: Single
Class: Real
Unit: 1 millimeter
Programmatic Pattern: GreaterEqualP[0 Milli Meter]
ColumnConnector
The connector on the instrument to which a column will be attached to.
Format: Multiple
[[1]] Connector Type
Header: Connector Type
Class: Expression
Programmatic Pattern: ConnectorP
[[2]] Thread Type
Header: Thread Type
Class: String
Programmatic Pattern: ThreadP
[[3]] Material
Header: Material
Class: Expression
Programmatic Pattern: MaterialP
[[4]] Gender
Header: Gender
Class: Expression
Programmatic Pattern: ConnectorGenderP
[[5]] Inner Diameter
Header: Inner Diameter
Class: Real
Unit: 1 millimeter
Programmatic Pattern: GreaterEqualP[0 Milli Meter]
[[6]] Outer Diameter
Header: Outer Diameter
Class: Real
Unit: 1 millimeter
Programmatic Pattern: GreaterEqualP[0 Milli Meter]
SystemPrimeGradients
List of the gradients used to purge the instrument lines at the start of an FPLC protocol for each chromatography type.
Format: Multiple
[[1]] Chromatography Type
Header: Chromatography Type
Class: Expression
Programmatic Pattern: SeparationModeP
[[2]] Gradient Method
Header: Gradient Method
Class: Link
Programmatic Pattern: _Link
Relation: Object[Method]
SystemFlushGradients
List of the gradients used to purge the instrument lines at the end of an FPLC protocol for each chromatography type.
Format: Multiple
[[1]] Chromatography Type
Header: Chromatography Type
Class: Expression
Programmatic Pattern: SeparationModeP
[[2]] Gradient Method
Header: Gradient Method
Class: Link
Programmatic Pattern: _Link
Relation: Object[Method]
Pricing Information
PricingRate
The rate charged by the ECL for time used on this instrument in the course of conducting user experiments.
Format: Single
Class: Real
Unit: 1 US dollar per hour
Programmatic Pattern: USD
Hold[GreaterEqualP[0 ----]]
Hour
PricingCategory
The generic billing category this instrument model will be listed under.
Format: Single
Class: String
Programmatic Pattern: PricingCategoryP
PricingLevel
With respect to cost, the category of devices, for which this Instrument falls into.
Format: Single
Class: Integer
Programmatic Pattern: GreaterEqualP[0, 1]
Compatibility
PlugRequirements
All electrical requirements for plug-in parts of this model.
Format: Multiple
[PlugNumber]
Header: PlugNumber
Class: Integer
[Phases]
Header: Phases
Class: Integer
[Voltage]
Header: Voltage
Class: Integer
Unit: 1 volt
[Current]
Header: Current
Class: Real
Unit: 1 ampere
[PlugType]
Header: PlugType
Class: String
AllowedPositions
Generates a pattern of all the valid position names for this model of instrument.
Format: Computable
Programmatic Pattern: _Alternatives
Expression: SafeEvaluate[{Field[Positions]}, Computables`Private`allowedPositions[Field[Positions]]]
WettedMaterials
A list of materials in the instrument which may be wetted by user-specified liquids.
Format: Multiple
Class: Expression
Programmatic Pattern: MaterialP
FacilityRequirementFiles
PDFs for facility requirements and pre-installation checkoff forms provided by the supplier for instruments of this model.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
Dimensions & Positions
Dimensions
The external dimensions of this model of instrument.
Format: Single
[[1]] DimensionX
Header: DimensionX
Class: Real
Unit: 1 meter
Programmatic Pattern: GreaterP[0 Meter]
[[2]] DimensionY
Header: DimensionY
Class: Real
Unit: 1 meter
Programmatic Pattern: GreaterP[0 Meter]
[[3]] DimensionZ
Header: DimensionZ
Class: Real
Unit: 1 meter
Programmatic Pattern: GreaterP[0 Meter]
CrossSectionalShape
The shape of this model of instrument in the X-Y plane.
Format: Single
Class: Expression
Programmatic Pattern: Circle | Rectangle
ContainerImage2DFile
A top-down (X-Y plane) image of this model of instrument which can be overlaid on a 2D container plot.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
Shape2D
A Graphics primitive corresponding to the 2D shape of this model of instrument.
Format: Single
Class: Expression
Programmatic Pattern: _Polygon | _Circle
Shape3D
A Graphics primitive corresponding to the 3D shape of this model of instrument.
Format: Single
Class: Expression
Programmatic Pattern: _Polygon
Positions
Spatial definitions of the positions that exist in this model of instrument.
Format: Multiple
[Name]
Header: Name
Class: String
[Footprint]
Header: Footprint
Class: Expression
[MaxWidth]
Header: MaxWidth
Class: Real
Unit: 1 meter
[MaxDepth]
Header: MaxDepth
Class: Real
Unit: 1 meter
[MaxHeight]
Header: MaxHeight
Class: Real
Unit: 1 meter
AvailableLayouts
Readily available configurations of container models in specified positions on the deck of this instrument model.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Model[DeckLayout][InstrumentModel]
Storage Information
LocalCacheContents
Items required to be present in the local cache for instruments of this model, along with the required quantity of each item.
Format: Multiple
[[1]] Item Model
Header: Item Model
Class: Link
Programmatic Pattern: _Link
[[2]] Required Quantity
Header: Required Quantity
Class: Integer
Programmatic Pattern: GreaterEqualP[0, 1]
ProvidedStorageCondition
The physical conditions such as temperature and humidity this instrument provides for samples stored long term within it.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Model[StorageCondition]
Plumbing Information
Connectors
Specifications for the ports on this model of instrument that may connect to other plumbing components.
Format: Multiple
[[1]] Connector Name
Header: Connector Name
Class: String
Programmatic Pattern: ConnectorNameP
[[2]] Connector Type
Header: Connector Type
Class: Expression
Programmatic Pattern: ConnectorP
[[3]] Thread Type
Header: Thread Type
Class: Expression
Programmatic Pattern: ThreadP|GroundGlassJointSizeP|None
[[4]] Inner Diameter
Header: Inner Diameter
Class: Real
Unit: 1 inch
Programmatic Pattern: GreaterP[0 Inch]
[[5]] Outer Diameter
Header: Outer Diameter
Class: Real
Unit: 1 inch
Programmatic Pattern: GreaterP[0 Inch]
[[6]] Gender
Header: Gender
Class: Expression
Programmatic Pattern: ConnectorGenderP|None
Wiring Information
WiringConnectors
Specifications for the wiring ends of this instrument that may plug into and conductively connect to other items, parts or instruments.
Format: Multiple
[[1]] Wiring Connector Name
Header: Wiring Connector Name
Class: String
Programmatic Pattern: WiringConnectorNameP
[[2]] Wiring Connector Type
Header: Wiring Connector Type
Class: Expression
Programmatic Pattern: WiringConnectorP
[[3]] Gender
Header: Gender
Class: Expression
Programmatic Pattern: ConnectorGenderP|None
Qualifications & Maintenance
QualificationFrequency
A list of the Qualifications which should be run on instruments of this model and their required frequencies.
Format: Multiple
[[1]] Qualification Model
Header: Qualification Model
Class: Link
Programmatic Pattern: _Link
Relation: Model[Qualification][Targets]
[[2]] Time
Header: Time
Class: Real
Unit: 1 day
Programmatic Pattern: GreaterP[0 Second]
MaintenanceFrequency
A list of the maintenance protocols which should be run on instruments of this model and their required frequencies.
Format: Multiple
[[1]] Maintenance Model
Header: Maintenance Model
Class: Link
Programmatic Pattern: _Link
Relation: Model[Maintenance][Targets]
[[2]] Time
Header: Time
Class: Real
Unit: 1 day
Programmatic Pattern: GreaterP[0 Second]
ReplacementParts
A list of tracked replacement part models for this instrument.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
PassiveClean
Indicates if the exterior surfaces of this instrument model can be cleaned while in use.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
VentilationFlowRate Requirement
The minimum flow rate of air generated by the instrument's ventilator for its safe and proper function.
Format: Single
Class: Real
Unit: 1 meter per second
Programmatic Pattern: Meter
Hold[GreaterP[0 ------]]
Second
VentilationFlowRate Recommendation
The flow rate of air generated by the instrument's ventilator recommended by its manufacturer.
Format: Single
Class: Real
Unit: 1 meter per second
Programmatic Pattern: Meter
Hold[GreaterP[0 ------]]
Second
ContinuousOperation
Indicates if the instrument is required to operate continuously in the lab, regardless of if it is InUse by a specific protocol, such as a freezer.
Format: Single
Class: Boolean
Programmatic Pattern: BooleanP
Inventory
Manufacturer
The company that originally manufactured this model of instrument.
Format: Single
Class: Link
Programmatic Pattern: _Link
SupportedInstruments
A list of instruments for which this model is an accompanying accessory.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Health & Safety
Sterile
Indicates that this model of instrument is used for protocols where SterileTechnique is indicated to be used.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
CultureHandling
Indicates the type of cellular samples (Mammalian or Microbial) that this instrument is used to handle.
Format: Single
Class: Expression
Programmatic Pattern: CellTypeP
GloveBoxStorage
Indiciates that this model of instrument permanently resides in the glove box.
Format: Single
Class: Boolean
Programmatic Pattern: BooleanP
HazardCategories
Hazards to be aware of during operation of instruments of this model.
Format: Multiple
Class: Expression
Programmatic Pattern: HazardCategoryP
SampleHandlingCategories
Special handling considerations that samples on this instrument require.
Format: Multiple
Class: Expression
Programmatic Pattern: HandlingCategoryP
Sensor Information
SensorBarrier
Type of sensors which cannot monitor the internal contents of instruments of this model from the outside.
Format: Multiple
Class: Expression
Programmatic Pattern: TypeP[Object[Sensor]]
General
DefaultMixer
The typical homogenization chamber in the device.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Alternatives[Model[Part, Mixer]]
Operating Limits
MinSampleVolume
The minimum volume that can be loaded on a single injection.
Format: Single
Class: Real
Unit: 1 microliter
Programmatic Pattern: GreaterEqualP[0 Micro Liter]
MaxSampleVolume
The maximum volume that can be loaded on a single injection.
Format: Single
Class: Real
Unit: 1 microliter
Programmatic Pattern: GreaterP[0 Micro Liter]
MinFlowRate
The minimum flow rate at which the instrument can pump buffer through the system.
Format: Single
Class: Real
Unit: 1 milliliter per minute
Programmatic Pattern: 0 Milli Liter
Hold[GreaterP[-------------]]
Minute
MaxFlowRate
The maximum flow rate at which the instrument can pump buffer through the system.
Format: Single
Class: Real
Unit: 1 milliliter per minute
Programmatic Pattern: 0 Milli Liter
Hold[GreaterP[-------------]]
Minute
MinAbsorbanceWavelength
The minimum wavelength that the detector's monochromator can be set to for absorbance filtering.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
MaxAbsorbanceWavelength
The maximum wavelength that the detector's monochromator can be set to for absorbance filtering.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Nano Meter, 1 Nano Meter]
AbsorbanceWavelengthBandpass
The range of wavelengths centered around the desired wavelength that the absorbance detector will measure. For e.g. if the bandpass is 10nm and the desired measurement wavelength is 260nm, the detector will measure wavelengths from 255nm - 265nm.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterEqualP[0 Nano Meter, 1 Nano Meter]
MinPressure
The minimum pressure at which the instrument can operate.
Format: Single
Class: Real
Unit: 1 pound‐force per inch squared
Programmatic Pattern: GreaterEqualP[0 PSI]
TubingMaxPressure
The maximum pressure the tubing in the sample flow path can tolerate.
Format: Single
Class: Real
Unit: 1 pound‐force per inch squared
Programmatic Pattern: GreaterP[0 PSI]
PumpMaxPressure
The maximum pressure that the pump can tolerate.
Format: Single
Class: Real
Unit: 1 pound‐force per inch squared
Programmatic Pattern: GreaterP[0 PSI]
FlowCellMaxPressure
The maximum pressure the detector's flow cell can tolerate.
Format: Single
Class: Real
Unit: 1 pound‐force per inch squared
Programmatic Pattern: GreaterEqualP[0 PSI]
Last modified on Mon 26 Sep 2022 15:43:54