Object[Calibration, Bufferbot]

A calibration that relates physical quantities to machine axis units on a liquid handler of bufferbot type.

Organizational Information

Qualifications & Maintenance

    ManufacturerCalibration

    Indicates if this calibration's fit function was provided by a manufacturer.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

    Reference

    The set of known data to which the response data points are calibrated.
    Format: Single
    Class: Compressed
    Programmatic Pattern: {NumericP..} | _?QuantityVectorQ

    Response

    The set of unknown, measured data points that are calibrated to the reference data points.
    Format: Single
    Class: Compressed
    Programmatic Pattern: {NumericP..} | _?QuantityVectorQ

    Anomalous

    Indicates if this calibration fell substantially out of historic values and must be investigated before being put into use in calculating measurements.
    Format: Single
    Class: Expression
    Programmatic Pattern: BooleanP

Analysis & Reports

    CalibrationFunction

    The pure function that represents the raw calibration fit between the reference and response data points.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    CalibrationStandardDeviation Function

    A function that computes single prediction error from a given x-value. Single prediction error is the expected error between a predicted y-value and a single obersvation of that value.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    CalibrationDistribution Function

    A function that computes single prediction distribution from a given x-value.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    FitAnalysis

    The fit analysis performed on this calibration data to generate the calibration function.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link

General

Experimental Results

    SmallCylinderCalibration Function

    The pure function that converts volumes to cylinder positions for the 10ml cylinder.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    MediumCylinderCalibration Function

    The pure function that converts volumes to cylinder positions for the 100ml cylinder.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    LargeCylinderCalibration Function

    The pure function that converts volumes to cylinder positions for the 1000ml cylinder.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    MediumCylinderPressure CalibrationFunction

    The pure function that converts pressures to raw pressure sensor/regulator settings for the 100ml cylinder.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    LargeCylinderPressure CalibrationFunction

    The pure function that converts pressures to raw pressure sensor/regulator settings for the 1000ml cylinder.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    MediumPlungerVelocity CalibrationFunction

    The pure function that converts velocity settings to raw plunger movement velocity signal values for the 100ml cylinder.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    LargePlungerVelocity CalibrationFunction

    The pure function that converts velocity settings to raw plunger movement velocity signal values for the 1000ml cylinder.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    SmallVesselpHProbeCalibration Function

    The pure function that converts raw sensor output to pH value for the small vessel's pH probe (15ml and 50ml tubes).
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    MediumVesselpHProbe CalibrationFunction

    The pure function that converts raw sensor output to pH value for the medium vessel's pH probe (0.25L to 5L).
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    LargeVesselpHProbeCalibration Function

    The pure function that converts raw sensor output to pH value for the large vessel's pH probe (10L and 20L).
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    MediumCylinderLowPosition

    The raw value of the plunger position when at the bottom of the 100ml cylinder.
    Format: Single
    Class: Integer
    Programmatic Pattern: GreaterP[0]

    LargeCylinderLowPosition

    The raw value of the plunger position when at the bottom of the 1000ml cylinder.
    Format: Single
    Class: Integer
    Programmatic Pattern: GreaterP[0]

    MediumCylinderWashPosition

    The raw value of the 100ml plunger position when ready for washing.
    Format: Single
    Class: Integer
    Programmatic Pattern: GreaterP[0]

    LargeCylinderWashPosition

    The raw value of the 1000ml plunger position when ready for washing.
    Format: Single
    Class: Integer
    Programmatic Pattern: GreaterP[0]

    OverheadStirCalibration Function

    The pure function that relates a desired rotational frequency for the overhead stirrer to a raw sensor array signal for the stirrer motor.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction

    HeaterCalibrationFunction

    The pure function that represents the raw calibration fit between the reference and response data points for the heating plate used in a Liquid Handler of Bufferbot type.
    Format: Single
    Class: Expression
    Programmatic Pattern: _Function | _QuantityFunction
Last modified on Mon 26 Sep 2022 15:43:43