Object[Calibration, pH]
A calibration for converting raw electrical signal(amperometric/potentiomeric) into the pH signal.
Organizational Information
Name
Name of this Object.
Format: Single
Class: String
Programmatic Pattern: _String
Pattern Description: A string.
ID
ID of this Object.
Format: Single
Class: String
Programmatic Pattern: _String
Pattern Description: The ID of this object.
Object
Object of this Object.
Format: Single
Class: Expression
Programmatic Pattern: Object[Calibration, pH, _String]
Pattern Description: The object reference of this object.
Type
Type of this Object.
Format: Single
Class: Expression
Programmatic Pattern: Object[Calibration, pH]
Pattern Description: Object[Calibration, pH]
Notebook
Notebook this object belongs to.
Format: Single
Class: Link
Programmatic Pattern: _Link
Pattern Description: An object of that matches ObjectP[Object[LaboratoryNotebook]].
Relation: Object[LaboratoryNotebook][Objects]
Author
The person who generated this calibration.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[User]
Maintenance
The recurring maintenance that generated this calibration.
Format: Single
Class: Link
Programmatic Pattern: _Link
Deprecated
Indicates if this calibration object is historical and would generate invalid data if used in the lab.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
Qualifications & Maintenance
ManufacturerCalibration
Indicates if this calibration's fit function was provided by a manufacturer.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
Reference
The set of known data to which the response data points are calibrated.
Format: Single
Class: Compressed
Programmatic Pattern: {NumericP..} | _?QuantityVectorQ
Response
The set of unknown, measured data points that are calibrated to the reference data points.
Format: Single
Class: Compressed
Programmatic Pattern: {NumericP..} | _?QuantityVectorQ
Anomalous
Indicates if this calibration fell substantially out of historic values and must be investigated before being put into use in calculating measurements.
Format: Single
Class: Expression
Programmatic Pattern: BooleanP
Probe
The designated probe that this calibration is intended to service.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Part, pHProbe]
Instrument
The designated conductivity device on which this was performed.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Instrument, pHMeter]
LowCalibrationTargetpH
The desired pH for the lowest pH standard.
Format: Single
Class: Real
Programmatic Pattern: GreaterEqualP[0]
LowCalibrationTemperature
The recorded temperature of the low pH calibration standard during the course of the calibration.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterEqualP[0 Kelvin]
MediumCalibrationTargetpH
The desired pH for the middle pH standard.
Format: Single
Class: Real
Programmatic Pattern: GreaterEqualP[0]
MediumCalibrationTemperature
The recorded temperature of the low pH calibration standard during the course of the calibration.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterEqualP[0 Kelvin]
HighCalibrationTargetpH
The desired pH for the high pH standard.
Format: Single
Class: Real
Programmatic Pattern: GreaterEqualP[0]
HighCalibrationTemperature
The recorded temperature of the low pH calibration standard during the course of the calibration.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterEqualP[0 Kelvin]
pHOffset
The y-intercept of the fitted slope.
Format: Single
Class: Real
Unit: 1 millivolt
Programmatic Pattern: UnitsP[Milli Volt]
pHFitRelativeError
The deviation of the measurements from the slope.
Format: Single
Class: Real
Unit: 1 percent
Programmatic Pattern: GreaterEqualP[0 Percent]
Analysis & Reports
CalibrationFunction
The pure function that represents the raw calibration fit between the reference and response data points.
Format: Single
Class: Expression
Programmatic Pattern: _Function | _QuantityFunction
CalibrationStandardDeviation Function
A function that computes single prediction error from a given x-value. Single prediction error is the expected error between a predicted y-value and a single obersvation of that value.
Format: Single
Class: Expression
Programmatic Pattern: _Function | _QuantityFunction
CalibrationDistribution Function
A function that computes single prediction distribution from a given x-value.
Format: Single
Class: Expression
Programmatic Pattern: _Function | _QuantityFunction
FitAnalysis
The fit analysis performed on this calibration data to generate the calibration function.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Analysis, Fit]
General
Protocol
The protocol that generated this data.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Alternatives[Object[Protocol, MeasurepH][CalibrationData]]
AnalyteData
All sample data associated with this calibration.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Data, pH][CalibrationData]
LowCalibrationBuffer
The pH 4 reference buffers used to calibrate the pH droplet probe used.
Format: Single
Class: Link
MediumCalibrationBuffer
The pH 7 reference buffers used to calibrate the pH probe used.
Format: Single
Class: Link
HighCalibrationBuffer
The pH 10 reference buffers used to calibrate the pH probe used.
Format: Single
Class: Link