Object[Method, FlowCytometry]

A method containing optics settings to run a flow cytometer experiment.

Organizational Information

    Name

    Name of this Object.
    Format: Single
    Class: String
    Programmatic Pattern: _String
    Pattern Description: A string.

    ID

    ID of this Object.
    Format: Single
    Class: String
    Programmatic Pattern: _String
    Pattern Description: The ID of this object.

    Object

    Object of this Object.
    Format: Single
    Class: Expression
    Programmatic Pattern: Object[Method, FlowCytometry, _String]
    Pattern Description: The object reference of this object.

    Type

    Type of this Object.
    Format: Single
    Class: Expression
    Programmatic Pattern: Object[Method, FlowCytometry]
    Pattern Description: Object[Method, FlowCytometry]

    Notebook

    Notebook this object belongs to.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link
    Pattern Description: An object of that matches ObjectP[Object[LaboratoryNotebook]].

General

    Template

    The method whose option selections should be selected as the default options for this method.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link

    MethodsTemplated

    Methods which were generated using this method's options as a starting point for its option defaults.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    Detector

    The detectors which should be used to detect light scattered off the samples.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: FlowCytometryDetectorP

    DetectionLabel

    For each member of Detector, the tag, including fluorescent or non-fluorescent chemical compounds or proteins, attached to the sample that will be analyzed by the Detectors.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link
    Relation: Alternatives[Model[Molecule]]

    ExcitationWavelength

    The wavelength(s) which should be used to excite fluorescence and scatter off the samples.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: FlowCytometryExcitationWavelengthP

    ExcitationPower

    For each member of ExcitationWavelength, the power which should be used to excite fluorescence and scatter off the samples.
    Format: Multiple
    Class: Real
    Unit: 1 milliwatt
    Programmatic Pattern: RangeP[0 Milli Watt, 100 Milli Watt]

    Gain

    For each member of Detector, the voltage the PMT should be set to to detect the scattered light off the sample.
    Format: Multiple
    Class: Real
    Unit: 1 volt
    Programmatic Pattern: GreaterEqualP[0 Volt]

    NeutralDensityFilter

    For each member of Detector, if a neutral density filter with an optical density of 2.0 should be used lower the intensity of scattered light that hits the detector.
    Format: Multiple
    Class: Boolean
    Programmatic Pattern: BooleanP