Object[Data, ChromatographyMassSpectra]
Analytical and mass spectrometry data captured during a chromatographic separation technique.
Organizational Information
Name
Name of this Object.
Format: Single
Class: String
Programmatic Pattern: _String
Pattern Description: A string.
ID
ID of this Object.
Format: Single
Class: String
Programmatic Pattern: _String
Pattern Description: The ID of this object.
Object
Object of this Object.
Format: Single
Class: Expression
Programmatic Pattern: Object[Data, ChromatographyMassSpectra, _String]
Pattern Description: The object reference of this object.
Type
Type of this Object.
Format: Single
Class: Expression
Programmatic Pattern: Object[Data, ChromatographyMassSpectra]
Pattern Description: Object[Data, ChromatographyMassSpectra]
Notebook
Notebook this object belongs to.
Format: Single
Class: Link
Programmatic Pattern: _Link
Pattern Description: An object of that matches ObjectP[Object[LaboratoryNotebook]].
Relation: Object[LaboratoryNotebook][Objects]
Replicates
Data acquired under replicated experimental conditions to this data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Data][Replicates]
General
Protocol
The protocol that generated this data.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Protocol][Data] | Object[Protocol][EnvironmentalData] | Object[Protocol, AbsorbanceQuantification][VolumeData] | Object[Protocol, AbsorbanceQuantification][EmptyPlateAbsorbance] | Object[Protocol, AbsorbanceQuantification][BufferAbsorbance] | Object[Protocol, AbsorbanceSpectroscopy][BlankAbsorbance] | Object[Protocol, AbsorbanceSpectroscopy][InitialPurgePressure] | Object[Protocol, AbsorbanceSpectroscopy][PurgePressureLog] | Object[Protocol, AbsorbanceIntensity][BlankAbsorbance] | Object[Protocol, AbsorbanceIntensity][InitialPurgePressure] | Object[Protocol, AbsorbanceIntensity][PurgePressureLog] | Object[Protocol, AbsorbanceKinetics][BlankAbsorbance] | Object[Protocol, AcousticLiquidHandling][Data] | Object[Protocol, AlphaScreen][GainOptimizationData] | Object[Protocol, AlphaScreen][FocalHeightOptimizationData] | Object[Protocol, BioLayerInterferometry][Data] | Object[Protocol, CyclicVoltammetry][ElectrodePretreatmentData] | Object[Protocol, CyclicVoltammetry][CyclicVoltammetryData] | Object[Protocol, CyclicVoltammetry][PostMeasurementStandardAdditionData] | Object[Protocol, CyclicVoltammetry][PretreatmentSpargingPressureLogs] | Object[Protocol, CyclicVoltammetry][SpargingPressureLogs] | Object[Protocol, CyclicVoltammetry][PostMeasurementStandardAdditionSpargingPressureLogs] | Object[Protocol, CircularDichroism][BlankData] | Object[Protocol, CircularDichroism][EmptyData] | Object[Protocol, DNASynthesis][DeblockSolutionWeightData] | Object[Protocol, DNASynthesis][WashSolutionWeightData] | Object[Protocol, DNASynthesis][InitialPurgePressure] | Object[Protocol, DynamicFoamAnalysis][Data] | Object[Protocol, Evaporate][CurrentWasteWeightData] | Object[Protocol, Evaporate][WasteWeightData] | Object[Protocol, Evaporate][BathActualTemperature] | Object[Protocol, Evaporate][BucketWeights] | Object[Protocol, PAGE][LadderData] | Object[Protocol, AgaroseGelElectrophoresis][LadderData] | Object[Protocol, MassSpectrometry][MatrixData] | Object[Protocol, MassSpectrometry][CalibrantData] | Object[Protocol, MassSpectrometry][SystemPrimeData] | Object[Protocol, MassSpectrometry][SystemFlushData] | Object[Protocol, HPLC][StandardData] | Object[Protocol, HPLC][BlankData] | Object[Protocol, HPLC][FlushData] | Object[Protocol, HPLC][PrimeData] | Object[Protocol, HPLC][SystemFlushData] | Object[Protocol, HPLC][SystemPrimeData] | Object[Protocol, HPLC][WasteWeightData] | Object[Protocol, FPLC][StandardData] | Object[Protocol, FPLC][BlankData] | Object[Protocol, FPLC][WasteWeightData] | Object[Protocol, FPLC][PrimeData] | Object[Protocol, FPLC][FlushData] | Object[Protocol, FPLC][SystemPrimeData] | Object[Protocol, FPLC][SystemFlushData] | Object[Protocol, GasChromatography][StandardData] | Object[Protocol, GasChromatography][BlankData] | Object[Protocol, GasChromatography][InitialHeliumPressure] | Object[Protocol, GasChromatography][InitialMethanePressure] | Object[Protocol, GasChromatography][FinalHeliumPressure] | Object[Protocol, GasChromatography][FinalMethanePressure] | Object[Protocol, GasChromatography][InitialHydrogenGeneratorWaterWeight] | Object[Protocol, GasChromatography][FinalHydrogenGeneratorWaterWeight] | Object[Protocol, IonChromatography][StandardData] | Object[Protocol, IonChromatography][AnionStandardData] | Object[Protocol, IonChromatography][CationStandardData] | Object[Protocol, IonChromatography][BlankData] | Object[Protocol, IonChromatography][AnionBlankData] | Object[Protocol, IonChromatography][CationBlankData] | Object[Protocol, IonChromatography][FlushData] | Object[Protocol, IonChromatography][AnionFlushData] | Object[Protocol, IonChromatography][CationFlushData] | Object[Protocol, IonChromatography][PrimeData] | Object[Protocol, IonChromatography][AnionPrimeData] | Object[Protocol, IonChromatography][CationPrimeData] | Object[Protocol, IonChromatography][SystemFlushData] | Object[Protocol, IonChromatography][AnionSystemFlushData] | Object[Protocol, IonChromatography][CationSystemFlushData] | Object[Protocol, IonChromatography][SystemPrimeData] | Object[Protocol, IonChromatography][AnionSystemPrimeData] | Object[Protocol, IonChromatography][CationSystemPrimeData] | Object[Protocol, IonChromatography][WasteWeightData] | Object[Protocol, ImageSample][RulerImageData] | Object[Protocol, MeasureViscosity][WasteWeightData] | Object[Protocol, PNASynthesis][WashSolutionWeightData] | Object[Protocol, PNASynthesis][PrimaryWasteWeightData] | Object[Protocol, PNASynthesis][SecondaryWasteWeightData] | Object[Protocol, PNASynthesis][PurgePressureData] | Object[Protocol, PNASynthesis][PurgePressureLog] | Object[Protocol, PNASynthesis][InitialPurgePressure] | Object[Protocol, PeptideSynthesis][WashSolutionWeightData] | Object[Protocol, PeptideSynthesis][PrimaryWasteWeightData] | Object[Protocol, PeptideSynthesis][SecondaryWasteWeightData] | Object[Protocol, PeptideSynthesis][PurgePressureData] | Object[Protocol, PeptideSynthesis][PurgePressureLog] | Object[Protocol, PeptideSynthesis][InitialPurgePressure] | Object[Protocol, Centrifuge][ContainerWeights] | Object[Protocol, Centrifuge][TareWeight] | Object[Protocol, Centrifuge][CollectionContainerWeights] | Object[Protocol, Centrifuge][CounterbalanceContainerTareWeights] | Object[Protocol, Centrifuge][CounterbalanceContainerWeights] | Object[Protocol, IncubateOld][CurrentTemperature] | Object[Protocol, Incubate][ThawActualTemperature] | Object[Protocol, Incubate][SonicationTemperatureData] | Object[Protocol, IRSpectroscopy][BlankData] | Object[Protocol, LCMS][StandardData] | Object[Protocol, LCMS][BlankData] | Object[Protocol, LCMS][PrimeData] | Object[Protocol, LCMS][FlushData] | Object[Protocol, LCMS][SystemPrimeData] | Object[Protocol, LCMS][SystemFlushData] | Object[Protocol, LCMS][CalibrationData] | Object[Protocol, MicrowaveDigestion][ReactionTemperature] | Object[Protocol, MicrowaveDigestion][ReactionPressure] | Object[Protocol, VacuumEvaporation][BucketWeights] | Object[Protocol, VacuumEvaporation][WasteWeightData] | Object[Protocol, SolidPhaseExtraction][PurgePressureLog] | Object[Protocol, SolidPhaseExtraction][InitialPurgePressure] | Object[Protocol, SolidPhaseExtraction][WasteWeightData] | Object[Protocol, SupercriticalFluidChromatography][StandardData] | Object[Protocol, SupercriticalFluidChromatography][BlankData] | Object[Protocol, SupercriticalFluidChromatography][PrimeData] | Object[Protocol, SupercriticalFluidChromatography][FlushData] | Object[Protocol, SupercriticalFluidChromatography][SystemPrimeData] | Object[Protocol, SupercriticalFluidChromatography][SystemFlushData] | Object[Protocol, SupercriticalFluidChromatography][WasteWeightData] | Object[Protocol, Transfer][TareWeights] | Object[Protocol][NitrogenPressureLog] | Object[Protocol][InitialNitrogenPressure] | Object[Protocol][CO2PressureLog] | Object[Protocol][InitialCO2Pressure] | Object[Protocol][ArgonPressureLog] | Object[Protocol][InitialArgonPressure] | Object[Protocol][WasteWeightTare] | Object[Protocol][SecondaryWasteWeightTare] | Object[Protocol][WasteWeight] | Object[Protocol][SecondaryWasteWeight] | Object[Protocol, UVMelting][InitialPurgePressure] | Object[Protocol, UVMelting][PurgePressureLog] | Object[Protocol, UVMelting][AbsorbanceData] | Object[Protocol, Filter][WasteWeightData] | Object[Protocol, MeasureDensity][TareWeights] | Object[Protocol, MeasureDensity][SampleWeights] | Object[Protocol, MeasureViscosity][WasteWeightData] | Object[Protocol, MeasureWeight][ScoutData] | Object[Protocol, MeasureWeight][TareData] | Object[Protocol, MeasureWeight][ResidueWeightData] | Object[Protocol, MeasureWeight][TareWeights] | Object[Protocol, qPCR][StandardData] | Object[Protocol, qPCR][BlankData] | Object[Protocol, CapillaryELISA][StandardData] | Object[Protocol, ELISA][StandardData] | Object[Protocol, ELISA][BlankData] | Object[Protocol, ELISA][PrereadData] | Object[Protocol, RNASynthesis][DeblockSolutionWeightData] | Object[Protocol, RNASynthesis][WashSolutionWeightData] | Object[Protocol, RNASynthesis][InitialPurgePressure] | Object[Protocol, MeasureOsmolality][ControlData] | Object[Protocol, MeasureOsmolality][VoidControlData] | Object[Protocol, MeasureOsmolality][PostRunInstrumentContaminationData] | Object[Protocol, Degas][HeliumPressureLog] | Object[Protocol, Degas][ChannelAGasPressure] | Object[Protocol, Degas][ChannelBGasPressure] | Object[Protocol, Degas][ChannelCGasPressure] | Object[Protocol, Degas][ChannelDGasPressure] | Object[Protocol, Degas][VacuumSensorPressure] | Object[Protocol, CapillaryGelElectrophoresisSDS][InjectionTable, Data] | Object[Protocol, CapillaryIsoelectricFocusing][InjectionTable, Data] | Object[Protocol, Nephelometry][BlankMeasurement] | Object[Protocol, NephelometryKinetics][BlankMeasurement] | Object[Protocol, MeasureDensity][AirCheckData] | Object[Protocol, MeasureDensity][WaterCheckData] | Object[Protocol, MeasureRefractiveIndex][Data]
Qualifications
The Qualifications that generated this data.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Qualification][Data] | Object[Qualification][WasteWeightTare] | Object[Qualification][SecondaryWasteWeightTare] | Object[Qualification][WasteWeight] | Object[Qualification][SecondaryWasteWeight] | Object[Qualification][EnvironmentalData] | Object[Qualification, CalibrateDNASynthesizer][InitialPurgePressure] | Object[Qualification, CalibrateDNASynthesizer][CalibrationWeightData] | Object[Qualification, EngineBenchmark][SelectedSensorData] | Object[Qualification, EngineBenchmark][RecordedSensorData] | Object[Qualification, ELISA][AbsorbanceQualificationData]
Maintenance
The maintenance that generated this data.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Maintenance][Data] | Object[Maintenance, CalibrateVolume][EmptyDistances] | Object[Maintenance, CalibrateVolume][TareDistance] | Object[Maintenance, CalibratePathLength][EmptyDistances] | Object[Maintenance, CalibratePathLength][StandardDistances] | Object[Maintenance, CalibratePathLength][EmptyAbsorbance] | Object[Maintenance][InitialNitrogenPressure] | Object[Maintenance][NitrogenPressureLog] | Object[Maintenance][InitialCO2Pressure] | Object[Maintenance][CO2PressureLog] | Object[Maintenance][InitialArgonPressure] | Object[Maintenance][ArgonPressureLog] | Object[Maintenance][EnvironmentalData] | Object[Maintenance][WasteWeightTare] | Object[Maintenance][SecondaryWasteWeightTare] | Object[Maintenance][WasteWeight] | Object[Maintenance][SecondaryWasteWeight] | Object[Maintenance, Flush][SystemFlushData]
Instrument
Instrument this data was obtained using.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Instrument]
Sensor
Sensor this data was obtained using.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Sensor][Data]
DataFile
The file containing the raw unprocessed data generated by the instrument.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
AliquotSamples
Aliquot samples that were directly assayed to generate this data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Sample][Data]
SamplesIn
Samples that were assayed to generate this data. Please note that if the samples were aliquoted, this field will contain the input samples.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
SamplesOut
Samples produced in the course of generating this data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Sample][Data]
DataType
Indicates if this data represents a blank, calibrant, standard, sample, column flush, or column prime measurement.
Format: Single
Class: Expression
Programmatic Pattern: ChromatographyMassSpectraP | Sample
InjectionIndex
The numeric position indicating when this data was measured for the experiment with respect to the other column primes, sample injections, standard injections, blank injections, and column flushes (e.g. 1 is the first measurement run).
Format: Single
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
DateInjected
The date and time the input sample was injected into the Instrument and measured.
Format: Single
Class: Date
Programmatic Pattern: _?DateObjectQ
SamplingMethod
The method used to inject the sample in a gas chromatography experiment.
Format: Single
Class: Expression
Programmatic Pattern: GCSamplingMethodP
SampleVolume
The volume taken from the input sample and injected into the Instrument.
Format: Single
Class: Real
Unit: 1 microliter
Programmatic Pattern: GreaterEqualP[0 Micro Liter]
SampleTemperature
The nominal temperature of autosampler chamber where samples are housed before injection.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterP[0 Celsius]
FluidType
The physical state of the mobile phase for the measurement.
Format: Single
Class: Expression
Programmatic Pattern: FluidCategoryP
SeparationMode
The type of chromatographic separation that categorizes the mobile (e.g. CosolventA/BufferA) and stationary phase used (e.g. Columns), ideally for optimal sample separation and resolution.
Format: Single
Class: Expression
Programmatic Pattern: SeparationModeP
Scale
Indicates if the SFC is intended to separate material (Preparative) and therefore collect fractions and/or analyze properties of the material (Analytical).
Format: Single
Class: Expression
Programmatic Pattern: Analytical | Preparative
Detectors
Indicates the types of measurements performed for the experiment and available on the Instrument.
Format: Multiple
Class: Expression
Programmatic Pattern: ChromatographyDetectorTypeP
AcquisitionMode
For experiments with MassSpectrometry available, the type of acquisition being performed in this protocol. MS mode measures the masses of the intact analytes, whereas MSMS measures the masses of the analytes fragmented by collision-induced dissociation.
Format: Single
Class: Expression
Programmatic Pattern: AcquisitionModeP
MassAnalyzer
For experiments with MassSpectrometry available, the type of the component of the mass spectrometer that performs ion separation based on m/z (mass-to-charge ratio). SingleQuadrupole selects ions individually for measurement.
Format: Single
Class: Expression
Programmatic Pattern: MassAnalyzerTypeP
IonSource
For experiments with MassSpectrometry available, the type of ionization used to create gas-phase ions from the molecules in the sample. Electrospray ionization (ESI) produces ions using an electrospray in which a high voltage is applied to a liquid to create an aerosol, and gas-phase ions are formed from the fine spray of charged droplets as a result of solvent evaporation and Coulomb fission.
Format: Single
Class: Expression
Programmatic Pattern: IonSourceP | GCIonSourceP
Columns
The stationary phase device(s) through which the Buffers or CO2/Cosolvents flow and analyte samples are injected into. It adsorbs and separates the molecules within the sample based on the properties of the Cosolvent, samples, column material, and ColumnTemperature.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Item][Data]
Column
The (first) stationary phase device through which the Buffers or CO2/Cosolvents flow and analyte samples are injected into. It adsorbs and separates the molecules within the sample based on the properties of the Cosolvent/Buffer, samples, column material, and ColumnTemperature.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Item][Data]
SecondaryColumn
The (first) stationary phase device through which the Buffers or CO2/Cosolvents flow and analyte samples are injected into. It adsorbs and separates the molecules within the sample based on the properties of the Cosolvent/Buffer, samples, column material, and ColumnTemperature.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Item][Data]
TertiaryColumn
The (first) stationary phase device through which the Buffers or CO2/Cosolvents flow and analyte samples are injected into. It adsorbs and separates the molecules within the sample based on the properties of the Cosolvent/Buffer, samples, column material, and ColumnTemperature.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Item][Data]
ColumnTemperature
The specified temperature of the Columns during the measurement.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterP[0 Celsius]
ColumnOrientation
The direction of the Columns with respect to the flow.
Format: Single
Class: Expression
Programmatic Pattern: ColumnOrientationP
GuardColumn
The protective stationary phase device often used to adsorb and sequester fouling contaminants from the Columns.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Item][Data]
GuardCartridge
The consumable replaced within the GuardColumn.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Item][Data]
GuardColumnOrientation
The direction of the GuardColumn for the protocol. If a Columns is used and GuardColumnOrientation is ReverseColumn, then the GuardColumn is placed after the column relative to the direction of the flow path.
Format: Single
Class: Expression
Programmatic Pattern: ColumnOrientationP
GradientMethod
Instructions for the mixing and distribution of the CO2 and Cosolvent/Buffer solutions within the mobile phase over time.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Method]
BufferA
The solvent connected to position A, the flow of which is directed by GradientA compositions for liquid chromatography.
Format: Single
Class: Link
Programmatic Pattern: _Link
BufferB
The solvent connected to position B, the flow of which is directed by GradientB compositions for liquid chromatography.
Format: Single
Class: Link
Programmatic Pattern: _Link
BufferC
The solvent connected to position C, the flow of which is directed by GradientC compositions for liquid chromatography.
Format: Single
Class: Link
Programmatic Pattern: _Link
BufferD
The solvent connected to position D, the flow of which is directed by GradientD compositions for liquid chromatography.
Format: Single
Class: Link
Programmatic Pattern: _Link
CosolventA
The solvent connected to position A, the flow of which is directed by GradientA compositions for SupercriticalFluidChromatography measurement.
Format: Single
Class: Link
Programmatic Pattern: _Link
CosolventB
The solvent connected to position B, the flow of which is directed by GradientB compositions for SupercriticalFluidChromatography measurement.
Format: Single
Class: Link
Programmatic Pattern: _Link
CosolventC
The solvent connected to position C, the flow of which is directed by GradientC compositions for SupercriticalFluidChromatography measurement.
Format: Single
Class: Link
Programmatic Pattern: _Link
CosolventD
The solvent connected to position D, the flow of which is directed by GradientD compositions for SupercriticalFluidChromatography measurement.
Format: Single
Class: Link
Programmatic Pattern: _Link
MakeupSolvent
The solution pumped and supplementing the column effluent on entry to the mass spectrometer.
Format: Single
Class: Link
Programmatic Pattern: _Link
CO2Gradient
The percentage of supercritical CO2 in the composition over time, in the form: {Time, % CO2} or a single % CO2 for the entire run.
Format: Single
Class: Expression
Programmatic Pattern: {{GreaterEqualP[0 Minute], RangeP[0 Percent, 100 Percent]}...} | RangeP[0 Percent, 100 Percent]
GradientA
For each member of SamplesIn, the percentage of BufferA or CosolventA in the composition over time, in the form: {Time, % BufferA|Cosolvent A} or a single % Buffer A|Cosolvent A for the entire run.
Format: Single
Class: Expression
Programmatic Pattern: {{GreaterEqualP[0 Minute], RangeP[0 Percent, 100 Percent]}...} | RangeP[0 Percent, 100 Percent]
GradientB
For each member of SamplesIn, the percentage of BufferB or CosolventB in the composition over time, in the form: {Time, % BufferB|Cosolvent B} or a single % Buffer B|Cosolvent B for the entire run.
Format: Single
Class: Expression
Programmatic Pattern: {{GreaterEqualP[0 Minute], RangeP[0 Percent, 100 Percent]}...} | RangeP[0 Percent, 100 Percent]
GradientC
For each member of SamplesIn, the percentage of BufferC or CosolventC in the composition over time, in the form: {Time, % BufferC|Cosolvent C} or a single % Buffer C|Cosolvent C for the entire run.
Format: Single
Class: Expression
Programmatic Pattern: {{GreaterEqualP[0 Minute], RangeP[0 Percent, 100 Percent]}...} | RangeP[0 Percent, 100 Percent]
GradientD
For each member of SamplesIn, the percentage of Buffer D or CosolventD in the composition over time, in the form: {Time, % BufferD|Cosolvent D} or a single % Buffer D|Cosolvent D for the entire run.
Format: Single
Class: Expression
Programmatic Pattern: {{GreaterEqualP[0 Minute], RangeP[0 Percent, 100 Percent]}...} | RangeP[0 Percent, 100 Percent]
BackPressure
The applied pressure between the atmosphere and the PhotoDiodeArray detector exit, in the form: {Time, BackPressure} or a single BackPressure for the entire run.
Format: Single
Class: Expression
Programmatic Pattern: {{GreaterEqualP[0 Minute], GreaterP[0 PSI]}...} | GreaterP[0 PSI]
FlowRates
The bulk speed of the mobile phase (Buffers or CO2/Cosolvents) at each time point where the slope changed.
Format: Multiple
[[1]] Time
Header: Time
Class: Real
Unit: 1 minute
[[2]] Flow Rate
Header: Flow Rate
Class: Real
Unit: 1 milliliter per minute
SeparationMethod
A collection of inlet, column, and oven parameters that will be used to perform the chromatographic separation after the sample has been injected.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Method]
SPMESampleExtractionTime
The amount of time the injection tool left the Solid Phase MicroExtraction (SPME) fiber in contact with the sample for adsorption of analytes onto the SPME fiber.
Format: Single
Class: Real
Unit: 1 minute
Programmatic Pattern: GreaterEqualP[0 Minute]
SPMESampleDesorptionTime
The amount of time the injection tool left the Solid Phase MicroExtraction (SPME) fiber exposed in the inlet vaporization chamber.
Format: Single
Class: Real
Unit: 1 minute
Programmatic Pattern: GreaterEqualP[0 Minute]
TransferLineTemperature
The temperature at which the segment of a gas chromatography column that extends out of the column oven and into the mass spectrometer is held during separation in a gas chromatograhph.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterEqualP[0 Kelvin]
SolventDelay
The amount of time into the separation after which the mass spectrometer will begin collecting mass spectra.
Format: Single
Class: Real
Unit: 1 minute
Programmatic Pattern: GreaterEqualP[0 Minute]
TraceIonDetection
Indicates whether a proprietary set of algorithms to reduce noise in ion abundance measurements during spectral collection, resulting in lower detection limits for trace compounds, will be used.
Format: Single
Class: Boolean
Programmatic Pattern: BooleanP
TuneFile
The file containing the raw tune data and tune report for a GC/MS experiment.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
StandardData
The data from the reference sample run before this data was generated.
Format: Single
Class: Link
Programmatic Pattern: _Link
Analytes
All samples associated with this standard.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
JCAMPDXFile
A JCAMPDX file containing the information present in the raw data, but in an unencrypted, widely recognized file type.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
MethodFiles
The method files used to conduct this mass spectrometry measurement for this sample zipped into one directory.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
Ionization
MassSpectrometryMethod
A redundant set of operating instructions for the mass analysis device during the generation of this data. Can be used for future experiments.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[Method]
IonMode
Indicates if positively or negatively charged ions are analyzed each run.
Format: Single
Class: Expression
Programmatic Pattern: IonModeP
MakeupFlowRate
The total rate of MakeupSolvent pumped through the Instrument for each measurement.
Format: Single
Class: Expression
Programmatic Pattern: Milliliter 0 Milli Liter
Hold[ListableP[{GreaterEqualP[0 Minute], GreaterEqualP[0 ----------]}] | GreaterEqualP[-------------]]
Minute Minute
ProbeTemperature
The temperature of the needle that introduces the column effluent into the spray chamber.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterP[0 Celsius]
DesolvationTemperature
The temperature setting for the ESI desolvation heater that controls the nitrogen gas temperature used for solvent evaporation to produce single gas phase ions from the ion spray.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterP[0 Celsius]
ESICapillaryVoltage
The applied voltage differential between the injector and the inlet plate for the mass spectrometry in order to ionize analyte molecules.
Format: Single
Class: Real
Unit: 1 volt
Programmatic Pattern: UnitsP[0 Volt]
SourceTemperature
The temperature that the source block is set to in order to discourage condensation and decrease solvent clustering in the reduced vacuum region of the source.
The source block is the metallic chamber with reduced pressure separating the sprayer (at atmospheric pressure) and the inside of the mass spectrometer (at 10^-7 Torr of pressure). It consists of the sampling cone, the isolation valve, and the ion block. The source temperature setting affects sensitivity.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterP[0 Celsius]
QuadrupoleTemperature
The temperature at which the quadrupole (the 4 parallel metal rods between which an oscillating electric field is produced that separates the ions by mass to charge ratio as they fly through the mass spectrometer) is set.
Format: Single
Class: Real
Unit: 1 degree Celsius
Programmatic Pattern: GreaterP[0 Celsius]
SourceVoltage
The applied voltage between the sample inlet on the mass spectrometry and the first stage of the ion filter.
Format: Single
Class: Real
Unit: 1 volt
Programmatic Pattern: GreaterP[0 Volt]
DeclusteringVoltage
The applied voltage between the sample inlet on the mass spectrometry and the first stage of the ion filter.
Format: Single
Class: Real
Unit: 1 volt
Programmatic Pattern: UnitsP[0 Volt]
ConeGasFlow
The rate of nitrogen gas flow ejected around the sample inlet cone (the spherical metal plate on the source block, acting as a first gate between the sprayer and the reduced-pressure ion block). This gas flow is used to minimize the formation of solvent ion clusters. It also helps reduce adduct ions and directs the spray into the ion block while keeping the sample cone clean.
Format: Single
Class: VariableUnit
Programmatic Pattern: 1 Liter
Hold[GreaterP[-------] | GreaterP[0 PSI]]
Hour
DesolvationGasFlow
The nitrogen gas flow ejected around the ESI (electrospray ionization) capillary, used for solvent evaporation to produce single gas phase ions from the ion spray.
Format: Single
Class: VariableUnit
Programmatic Pattern: 1 Liter
Hold[GreaterP[-------] | GreaterP[0 PSI]]
Hour
StepwaveVoltage
The applied voltage between the two stages of the ion filter.
Format: Single
Class: Real
Unit: 1 volt
Programmatic Pattern: GreaterP[0 Volt]
Mass Analysis
SamplingConeVoltage
The voltage offset between the 1st and 2nd stage of the stepwave ion guide which leads ions coming from the sample cone (the metal shield covering the front of the source block), towards the quadrupole mass analyzer.
Format: Single
Class: Real
Unit: 1 volt
Programmatic Pattern: GreaterP[0 Volt]
AcquisitionWindows
The time blocks to acquire measurement.
Format: Multiple
[StartTime]
Header: StartTime
Class: Real
Unit: 1 minute
[EndTime]
Header: EndTime
Class: Real
Unit: 1 minute
AcquisitionModes
For each member of AcquisitionWindows, the manner of scanning and/or fragmenting intact and resultant ions.
Format: Multiple
Class: Expression
Programmatic Pattern: MSAcquisitionModeP | MS1 | MS1MS2
Fragmentations
For each member of AcquisitionWindows, indicates whether the intact ions collide with inert gas to dissociate into product ions. Also known as Tandem mass spectrometry or MS/MS.
Format: Multiple
Class: Boolean
Programmatic Pattern: BooleanP
MinMass
The lowest measured mass-to-charge ratio (m/z) value.
Format: Single
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: 0 Gram
Hold[GreaterEqualP[------]]
Mole
MaxMass
The highest measured mass-to-charge ratio (m/z) value.
Format: Single
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: 0 Gram
Hold[GreaterP[------]]
Mole
MinMasses
For each member of AcquisitionWindows, the lowest measured or selected mass-to-charge ratio (m/z) intact ions.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: 0 Gram
Hold[GreaterEqualP[------]]
Mole
MaxMasses
For each member of AcquisitionWindows, the highest measured or selected mass-to-charge ratio (m/z) intact ions.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: 0 Gram
Hold[GreaterP[------]]
Mole
MassRanges
For each member of AcquisitionWindows, the lower and upper bounds of the mass-to-charge ratios (m/z) that were scanned across during measurement.
Format: Multiple
[[1]] First m/z
Header: First m/z
Class: Real
Programmatic Pattern: GreaterP[0]
[[2]] Last m/z
Header: Last m/z
Class: Real
Programmatic Pattern: GreaterP[0]
MassSelection
The all of the ions tabulated by mass-to-charge ratio (m/z) measured via mass spectrometry.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: 0 Gram
Hold[GreaterP[------]]
Mole
MassSelections
For each member of AcquisitionWindows, all of the measured or selected mass-to-charge ratio (m/z) intact ions.
Format: Multiple
Class: Expression
Programmatic Pattern: 0 Gram
Hold[{GreaterP[------]..}]
Mole
MassSelectionDwellTimes
For each member of AcquisitionWindows, the amount of time that was spent counting ions at all of the measured or selected mass-to-charge ratio (m/z) intact ions.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterP[0 Second]..}
MassRangeScanSpeeds
For each member of AcquisitionWindows, the speed (in m/z per second) at which the mass spectrometer will collect data.
Format: Multiple
Class: Real
Programmatic Pattern: GreaterEqualP[0]
MassRangeThresholds
For each member of AcquisitionWindows, the minimum mass abundance above which the mass spectrometer will collect data.
Format: Multiple
Class: Real
Programmatic Pattern: GreaterEqualP[0]
MassSelectionResolutions
For each member of AcquisitionWindows, the m/z range window that may be transmitted through the quadrupole at the selected mass.
Format: Multiple
Class: Expression
Programmatic Pattern: Low | High
MassSelectionDetectionGains
For each member of AcquisitionWindows, the gain factor that was used during the collection of the corresponding list of selectively monitored m/z in MassSelection.
Format: Multiple
Class: Real
Programmatic Pattern: GreaterEqualP[0]
ScanTime
The duration of time allowed to pass between each spectral acquisition.
Format: Single
Class: Real
Unit: 1 second
Programmatic Pattern: GreaterP[0 Second]
ScanTimes
For each member of AcquisitionWindows, the duration of time allowed to pass between each spectral acquisition.
Format: Multiple
Class: Real
Unit: 1 second
Programmatic Pattern: GreaterP[0 Second]
ScanSpeeds
For each member of AcquisitionWindows, the rate at which the mass ranges indicated were scanned across.
Format: Multiple
Class: Real
Unit: 1 second
Programmatic Pattern: GreaterP[0 Second]
FragmentMinMasses
For each member of AcquisitionWindows, the lowest measured or selected mass-to-charge ratio (m/z) dissociation product ions.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: 0 Gram
Hold[GreaterEqualP[------]]
Mole
FragmentMaxMasses
For each member of AcquisitionWindows, the highest measured or selected mass-to-charge ratio (m/z) dissociation product ions.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: 0 Gram
Hold[GreaterP[------]]
Mole
FragmentMassSelections
For each member of AcquisitionWindows, all of the measured or selected mass-to-charge ratio (m/z) dissociation product ions.
Format: Multiple
Class: Expression
Programmatic Pattern: 0 Gram
Hold[{GreaterP[------]..}]
Mole
CollisionEnergies
For each member of AcquisitionWindows, all of the measured or selected mass-to-charge ratio (m/z) dissociation product ions.
Format: Multiple
Class: Expression
Programmatic Pattern: {UnitsP[0 Volt]..} | UnitsP[0 Volt]
LowCollisionEnergies
For each member of AcquisitionWindows, the lowest value of the linear function for applied potential as mapped to the MinMass.
Format: Multiple
Class: Real
Unit: 1 volt
Programmatic Pattern: GreaterP[0 Volt]
HighCollisionEnergies
For each member of AcquisitionWindows, the highest value of the linear function for applied potential as mapped to the MinMass.
Format: Multiple
Class: Real
Unit: 1 volt
Programmatic Pattern: GreaterP[0 Volt]
FinalLowCollisionEnergies
For each member of AcquisitionWindows, at the end of the spectral scan, the lowest value of the linear function for applied potential as mapped to the MinMass.
Format: Multiple
Class: Real
Unit: 1 volt
Programmatic Pattern: GreaterP[0 Volt]
FinalHighCollisionEnergies
For each member of AcquisitionWindows, at the end of the spectral scan, the highest value of the linear function for applied potential as mapped to the MinMass.
Format: Multiple
Class: Real
Unit: 1 volt
Programmatic Pattern: GreaterP[0 Volt]
FragmentScanTimes
For each member of AcquisitionWindows, the duration of time allowed to pass between each spectral acquisition for the product ions when AcquistionMode -> DataDependent.
Format: Multiple
Class: Real
Unit: 1 second
Programmatic Pattern: GreaterP[0 Second]
AcquisitionSurveys
For each member of AcquisitionWindows, indicates the number of intact ions to consider for fragmentation and acquisition in DataDependent acquistion mode.
Format: Multiple
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
MinimumThresholds
For each member of AcquisitionWindows, the least number of total intact ions needed to be measured to elicit an acquisition program.
Format: Multiple
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
AcquisitionLimits
For each member of AcquisitionWindows, the maximum number measured ions allowed during a fragmentation measurement of a survey ion. Will proceed to the next intact ion/fragmentation once reached.
Format: Multiple
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
CycleTimeLimits
For each member of AcquisitionWindows, the maximum duration allowable for a survey. Will proceed to the next cycle once reached.
Format: Multiple
Class: Real
Unit: 1 second
Programmatic Pattern: GreaterP[0 Second]
ExclusionDomains
For each member of AcquisitionWindows, the time blocks within to consider for specific mass exclusion.
Format: Multiple
Class: Expression
Programmatic Pattern: {{UnitsP[Minute], UnitsP[Minute]}..}
ExclusionMasses
For each member of AcquisitionWindows, indicates the manner of omitting intact ions for acquisition survey.
Format: Multiple
Class: Expression
Programmatic Pattern: 0 Gram
Hold[{{ExclusionModeP, GreaterP[------]}..}]
Mole
ExclusionMassTolerances
For each member of AcquisitionWindows, the range above and below each ion in ExclusionMassSelection to consider for omission.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: GreaterP[0 Dalton]
ExclusionRetentionTime Tolerances
For each member of AcquisitionWindows, the range above and below each retention time in ExclusionMassSelection to consider for omission.
Format: Multiple
Class: Real
Unit: 1 second
Programmatic Pattern: GreaterP[0 Second]
InclusionDomains
For each member of AcquisitionWindows, the time blocks within to consider for specific mass inclusion.
Format: Multiple
Class: Expression
Programmatic Pattern: {{UnitsP[Minute], UnitsP[Minute]}..}
InclusionMasses
For each member of AcquisitionWindows, the intact ions to prioritize during survey acquisition.
Format: Multiple
Class: Expression
Programmatic Pattern: 0 Gram
Hold[{{InclusionModeP, GreaterP[------]}..}]
Mole
InclusionCollisionEnergies
For each member of AcquisitionWindows, the overriding collision energy to use for the corresponding InclusionMass.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterEqualP[0 Volt]..}
InclusionDeclusteringVoltages
For each member of AcquisitionWindows, the overriding source voltage to use for the corresponding InclusionMass.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterEqualP[0 Volt]..}
InclusionChargeStates
For each member of AcquisitionWindows, the charge state isotopes to also consider for inclusion.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterEqualP[0, 1]..}
InclusionScanTimes
For each member of AcquisitionWindows, the overriding scan time to use for the corresponding InclusionMass.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterEqualP[0 Second]..}
InclusionMassTolerances
For each member of AcquisitionWindows, the range above and below each ion in InclusionMassSelection to consider for omission.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: GreaterP[0 Dalton]
ChargeStateLimits
For each member of AcquisitionWindows, the number of ions to survey before excluding for ion state properties.
Format: Multiple
Class: Integer
Programmatic Pattern: GreaterP[0, 1]
ChargeStateSelections
For each member of AcquisitionWindows, the specific ionic states of intact ions to redundantly exclude from the survey for further fragmentation/acquisition.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterEqualP[1, 1]..}
ChargeStateMassTolerances
For each member of AcquisitionWindows, the range of m/z to consider for exclusion by ionic state property.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: GreaterP[0 Dalton]
IsotopeMassDifferences
For each member of AcquisitionWindows, the delta between monoisotopic ions as a criterion for survey exclusion.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterP[0 Dalton]..}
IsotopeRatios
For each member of AcquisitionWindows, the minimum relative magnitude between monoisotopic ions as a criterion for survey exclusion.
Format: Multiple
Class: Expression
Programmatic Pattern: {GreaterP[0]..}
IsotopeDetectionMinimums
For each member of AcquisitionWindows, the acquisition rate of a given intact mass to consider for isotope exclusion in the survey.
Format: Multiple
Class: Expression
Programmatic Pattern: 1
Hold[{GreaterP[0 ------]..}]
Second
IsotopeRatioTolerances
For each member of AcquisitionWindows, the range of relative magnitude around IsotopeRatio and SecondaryIsotopeRatio to consider for isotope exclusion.
Format: Multiple
Class: Real
Unit: 1 percent
Programmatic Pattern: GreaterP[0 Percent]
IsotopeMassTolerances
For each member of AcquisitionWindows, the range of m/z to consider for exclusion by ionic state property.
Format: Multiple
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: GreaterP[0 Dalton]
MassDetectionGain
Indicates the arbitrary-scaled signal amplification of the mass spectrometry measurement.
Format: Single
Class: Real
Programmatic Pattern: RangeP[0.01, 1000., 0.01]
MassDetectionGains
For each member of AcquisitionWindows, indicates the arbitrary-scaled signal amplification of the mass spectrometry measurement.
Format: Multiple
Class: Real
Programmatic Pattern: RangeP[0.01, 1000., 0.01]
Absorbance Measurement
AbsorbanceSelection
All the measured wavelengths of light absorbed in the detector's flow cell for a PhotoDiodeArray (PDA) detector.
Format: Multiple
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Centimeter]
MinAbsorbanceWavelength
The minimum wavelength of light detected by the PhotoDiodeArray (PDA) detector during the experiment.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Meter]
MaxAbsorbanceWavelength
The maximum wavelength of light detected by the PDA detector during the experiment.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Meter]
AbsorbanceWavelength Resolution
The increment in wavelengths spanning from MinWavelength to MaxWavelength for PDA detector measurement.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Meter]
UVFilter
Indicates whether or not UV light (less than 210 nm) were transmitted through the sample for PDA detector.
Format: Single
Class: Boolean
Programmatic Pattern: BooleanP
AbsorbanceSamplingRate
Indicates the frequency of measurement for the PDA detectors.
Format: Single
Class: Real
Unit: 1 reciprocal second
Programmatic Pattern: 1
Hold[GreaterP[0 ------]]
Second
Data Processing
CalibrantSample
The sample with known and formulated analytes used to calibrate the instrument prior to collect this data.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Alternatives[Object[Sample]]
Calibrant
Mass spectrum of the calibrant used to calibrate the instrument prior to collect this data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Alternatives[Object[Data, ChromatographyMassSpectra][Analytes]]
CalibrationStandardDeviation
The measured variance between multiple readings of the Calibrant sample.
Format: Single
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: 0 Gram
Hold[GreaterEqualP[------]]
Mole
IonAbundanceMass
The selected mass-to-charge ratio used to inform the chromatogram within IonAbundance field. If MassSelection is specified as individual entries, then the first is taken. If MassSelection is a range, then the most abundant m/z from MassSpectrum is chosen.
Format: Single
Class: Real
Unit: 1 gram per mole
Programmatic Pattern: Gram
Hold[GreaterP[0 ----]]
Mole
AbsorbanceWavelength
The primary wavelength of light absorbed in the Instrument's PhotoDiodeArray (PDA) detector used to select the chromatogram for Absorbance. If AbsorbanceSelection is specified as individual entries, then the first is taken. If AbsorbanceSelection is a range, then the most absorbing wavelength is chosen.
Format: Single
Class: Real
Unit: 1 nanometer
Programmatic Pattern: GreaterP[0 Meter]
MassSpectrometryFiles
The files containing the mass spectrometry data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
AbsorbanceFile
The file containing the absorbance data.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
PressureFile
The file containing the raw chromatography pressure data.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
TemperatureFile
The file containing the raw chromatography temperature data.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
Experimental Results
MassSpectrum
Spectrum of observed mass-to-charge (m/z) ratio vs peak intensity for this analyte, calibrant, or matrix sample detected by the Instrument. This is the summed signal from all IonAbundance3D acquired by the Instrument over the time course of measurement.
Format: Single
Class: QuantityArray
Unit: ['1 gram per mole', '1 ArbitraryUnits']
Programmatic Pattern: Gram
Hold[QuantityCoordinatesP[{----, ArbitraryUnit}]]
Mole
UnintegratedMassSpectra
Mass spectra of observed mass-to-charge ratio (m/z) vs. intensity during the course of the direct injection experiment.
Format: Multiple
[[1]] Time
Header: Time
Class: Real
Unit: 1 minute
[[2]] Mass Spectrum
Header: Mass Spectrum
Class: BigQuantityArray
Unit: ['1 gram per mole', '1 ArbitraryUnits']
ReactionMonitoringIntensity
The total intensity of each ion selection (MS1 only) or reactions (MS1/MS2) monitored over time.
Format: Single
Class: BigQuantityArray
Unit: ['1 gram per mole', '1 gram per mole', '1 ArbitraryUnits']
Programmatic Pattern: Gram Gram
Hold[BigQuantityArrayP[{----, ----, ArbitraryUnit}]]
Mole Mole
ReactionMonitoringMass Chromatogram
The measured counts of intensity changes of different MultipleReactionMonitoring Assays (MS1/MS2 mass pairs) and Mass Selection Values (MS1 value only) during the course of the experiment for the MassSpectrometry detector. Each entry is {MS1 m/z, MS2 m/z, {Time,Intensity}}.
Format: Multiple
[[1]] Mass Selection
Header: Mass Selection
Class: Real
Unit: 1 gram per mole
[[2]] Fragment Mass Selection
Header: Fragment Mass Selection
Class: Real
Unit: 1 gram per mole
[[3]] Mass Chromatogram
Header: Mass Chromatogram
Class: BigQuantityArray
Unit: ['1 minute', '1 ArbitraryUnits']
IonMonitoringIntensity
The total intensity of each ion selection (MS1 value) in SelectedIonMonitoring mode, monitored over time.
Format: Single
Class: BigQuantityArray
Unit: ['1 gram per mole', '1 ArbitraryUnits']
Programmatic Pattern: Gram
Hold[BigQuantityArrayP[{----, ArbitraryUnit}]]
Mole
IonMonitoringMassChromatogram
The measured counts of intensity changes of different Mass Selection Values (MS1 value only) during the course of the experiment for the MassSpectrometry detector. Each entry is {MS1 m/z, {Time,Intensity}}.
Format: Multiple
[[1]] Mass Selection
Header: Mass Selection
Class: Real
Unit: 1 gram per mole
[[2]] Mass Chromatogram
Header: Mass Chromatogram
Class: BigQuantityArray
Unit: ['1 minute', '1 ArbitraryUnits']
IonAbundance
The chromatogram of counts for a singular IonAbundanceMass m/z vs. time during the course of the experiment for the MassSpectrometry detector.
Format: Single
Class: QuantityArray
Unit: ['1 minute', '1 ArbitraryUnits']
Programmatic Pattern: QuantityCoordinatesP[{Minute, ArbitraryUnit}]
TotalIonAbundance
The chromatogram of counts for the sum of all m/z measured during a single collection cycle vs. time during the course of the experiment for the MassSpectrometry detector.
Format: Single
Class: QuantityArray
Unit: ['1 minute', '1 ArbitraryUnits']
Programmatic Pattern: QuantityCoordinatesP[{Minute, ArbitraryUnit}]
IonAbundance3D
The measured counts of intact ions at each m/z for each retention time point during the course of the experiment for the MassSpectrometry detector. Each entry is {Time, MS1 m/z, IonAbundance}.
Format: Single
Class: BigQuantityArray
Unit: ['1 minute', '1 gram per mole', '1 ArbitraryUnits']
Programmatic Pattern: Gram
Hold[BigQuantityArrayP[{Minute, ----, ArbitraryUnit}]]
Mole
FragmentationIonAbundance3D
The measured counts of dissociated ion for a given spectral scan at time point during the course of the experiment for the MassSpectrometry detector. Each entry is {Time, MS2, IonAbundance}. May be split to LowCollisionEnergyIonAbundance3D and HighCollisionEnergyIonAbundance3D instead.
Format: Single
Class: BigQuantityArray
Unit: ['1 minute', '1 gram per mole', '1 ArbitraryUnits']
Programmatic Pattern: Gram
Hold[BigQuantityArrayP[{Minute, ----, ArbitraryUnit}]]
Mole
LowCollisionEnergyIon Abundance3D
Fragment mass spectra for when collision energy is ramping. Corresponds to the low collision energy.
Format: Multiple
[[1]] Time
Header: Time
Class: Real
Unit: 1 minute
[[2]] Parent Mass
Header: Parent Mass
Class: Real
Unit: 1 gram per mole
[[3]] Mass Spectrum
Header: Mass Spectrum
Class: BigQuantityArray
Unit: ['1 gram per mole', '1 ArbitraryUnits']
HighCollisionEnergyIon Abundance3D
Fragment mass spectra for when collision energy is ramping. Corresponds to the high collision energy.
Format: Multiple
[[1]] Time
Header: Time
Class: Real
Unit: 1 minute
[[2]] Parent Mass
Header: Parent Mass
Class: Real
Unit: 1 gram per mole
[[3]] Mass Spectrum
Header: Mass Spectrum
Class: BigQuantityArray
Unit: ['1 gram per mole', '1 ArbitraryUnits']
SurveyMassSpectra
Mass spectra of observed mass-to-charge ratio (m/z) vs. intensity used to conduct fragmentation analysis when AcquisitionMode includes DataDependent.
Format: Multiple
[[1]] Time
Header: Time
Class: Real
Unit: 1 minute
[[2]] Mass Spectrum
Header: Mass Spectrum
Class: BigQuantityArray
Unit: ['1 gram per mole', '1 ArbitraryUnits']
SurveyFragmentationMass Spectra
Mass spectra of observed mass-to-charge ratio (m/z) vs. intensity used to conduct fragmentation analysis when AcquisitionMode includes DataDependent.
Format: Multiple
[[1]] Time
Header: Time
Class: Real
Unit: 1 minute
[[2]] Parent Mass
Header: Parent Mass
Class: Real
Unit: 1 gram per mole
[[3]] Mass Spectrum
Header: Mass Spectrum
Class: BigQuantityArray
Unit: ['1 gram per mole', '1 ArbitraryUnits']
Absorbance
The chromatogram of absorbance at AbsorbanceWavelength vs. time during the course of the experiment for the PDA detector.
Format: Single
Class: QuantityArray
Unit: ['1 minute', '1 milli AbsorbanceUnit']
Programmatic Pattern: QuantityCoordinatesP[{Minute, Milli AbsorbanceUnit}]
Absorbance3D
The measured Absorbance at each Wavelength for each retention time point during the course of the experiment for the PhotoDiodeArray (PDA) detector.
Format: Single
Class: BigQuantityArray
Unit: ['1 minute', '1 nanometer', '1 milli AbsorbanceUnit']
Programmatic Pattern: BigQuantityArrayP[{Minute, Meter Nano, AbsorbanceUnit Milli}]
Pressure
The chromatogram of system pressure vs. time during the course of the experiment.
Format: Single
Class: QuantityArray
Unit: ['1 minute', '1 pound‐force per inch squared']
Programmatic Pattern: QuantityCoordinatesP[{Minute, PSI}]
Temperature
The chromatogram of column temperature vs. time during the course of the experiment.
Format: Single
Class: QuantityArray
Unit: ['1 minute', '1 degree Celsius']
Programmatic Pattern: QuantityCoordinatesP[{Minute, Celsius}]
RawDataFile
The file containing all raw data pertaining to the mass spectrometry measurement of this sample zipped into one directory.
Format: Single
Class: Link
Programmatic Pattern: _Link
Relation: Object[EmeraldCloudFile]
Analysis & Reports
ChromatogramComposition Analyses
Sample composition analyses performed on the Absorbance.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
IonAbundance3DPeaksAnalyses
Peak picking analyses performed on the IonAbundance3D data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Analysis][Reference]
IonAbundancePeaksAnalyses
Peak picking analyses performed on the IonAbundance data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Analysis][Reference]
MassSpectrumPeaksAnalyses
Peak picking analyses performed on the MassSpectrum data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Analysis][Reference]
AbsorbancePeaksAnalyses
Peak picking analyses performed on the Absorbance.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Analysis][Reference]
Absorbance3DPeaksAnalyses
Peak picking analyses performed on the Absorbance3D.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Analysis][Reference]
SmoothingAnalyses
Smoothing analysis performed on this data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Analysis][Reference]
DownsamplingAnalyses
Downsampling analyses performed on this data.
Format: Multiple
Class: Link
Programmatic Pattern: _Link
Relation: Object[Analysis][Reference]
Last modified on Mon 26 Sep 2022 15:43:44