Object[Data, AbsorbanceIntensity]

Measurements of absorbance intensity for a wavelength generated by the plate readers or UV/Vis Spectrophotometers.

Organizational Information

    Name

    Name of this Object.
    Format: Single
    Class: String
    Programmatic Pattern: _String
    Pattern Description: A string.

    ID

    ID of this Object.
    Format: Single
    Class: String
    Programmatic Pattern: _String
    Pattern Description: The ID of this object.

    Object

    Object of this Object.
    Format: Single
    Class: Expression
    Programmatic Pattern: Object[Data, AbsorbanceIntensity, _String]
    Pattern Description: The object reference of this object.

    Type

    Type of this Object.
    Format: Single
    Class: Expression
    Programmatic Pattern: Object[Data, AbsorbanceIntensity]

    Notebook

    Notebook this object belongs to.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link
    Pattern Description: An object of that matches ObjectP[Object[LaboratoryNotebook]].

    Replicates

    Data acquired under replicated experimental conditions to this data.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

General

Absorbance Measurement

    AcquisitionMixRate

    Indicates if the rate at which the samples within the cuvette should be mixed with a stir bar during data acquisition.
    Format: Single
    Class: Real
    Unit: 1 revolution per minute
    Programmatic Pattern: GreaterP[0 RPM]

    NominalAcquisitionMixRate

    Indicates the target/set rate at which the samples within the cuvette should be mixed with a stir bar during data acquisition.
    Format: Single
    Class: Real
    Unit: 1 revolution per minute
    Programmatic Pattern: GreaterP[0 RPM]

    ActualAcquisitionMixRate

    Indicates the absolute/exact rate at which the samples within the cuvette attained during data acquisition.
    Format: Single
    Class: Real
    Unit: 1 revolution per minute
    Programmatic Pattern: GreaterP[0 RPM]

    StirringError

    Indicates if stable stirring was not achieved within the cuvette after MaxStirAttempts during the setup of the assay.
    Format: Single
    Class: Boolean
    Programmatic Pattern: BooleanP

Experimental Results

    Absorbance

    The absorbance measured at the wavelength, with the blank absorbance subtracted (if available).
    Format: Single
    Class: Real
    Unit: 1 AbsorbanceUnit
    Programmatic Pattern: UnitsP[AbsorbanceUnit]

    Temperature

    The temperature in the instrument's sample compartment at the specified wavelength as it was recorded.
    Format: Single
    Class: Real
    Unit: 1 degree Celsius
    Programmatic Pattern: GreaterP[0 Kelvin]

    BlankAbsorbance

    A blank absorbance reading which includes absorbance from the buffer and container but without any analyte present.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link

    AnalyteAbsorbances

    Any absorbance data which use this data as a blank reading to subtract baseline signal due to the buffer or container rather than the analyte.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

    Blank

    A blank absorbance data which includes absorbance from the buffer and container but without any analyte present.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link

    Analytes

    Any absorbance data which use this data as a blank spectra to subtract baseline signal due to the buffer or container rather than the analyte.
    Format: Multiple
    Class: Link
    Programmatic Pattern: _Link

Data Processing

    UnblankedAbsorbance

    The raw, unblanked absorbance measured at the wavelength without the blank absorbance subtracted.
    Format: Single
    Class: Real
    Unit: 1 AbsorbanceUnit
    Programmatic Pattern: UnitsP[AbsorbanceUnit]

    RawAbsorbanceSpectrum

    The absorbance measured at the wavelength, without any blank subtraction, baseline correction, or smoothing applied by instrument software.
    Format: Single
    Class: QuantityArray
    Unit: ['1 nanometer', '1 AbsorbanceUnit']
    Programmatic Pattern: QuantityCoordinatesP[{Nanometer, AbsorbanceUnit}]

    DataType

    Whether this data represents an empty plate, blank, or analyte absorbance reading.
    Format: Single
    Class: Expression
    Programmatic Pattern: AbsorbanceSpectroscopyDataTypeP

Analysis & Reports

Physical Properties

    MassConcentration

    The most recently calculated mass of the constituent(s) divided by the volume of the mixture.
    Format: Single
    Class: Real
    Unit: 1 gram per liter
    Programmatic Pattern: 0 Gram Hold[GreaterEqualP[------]] Liter