ecl-logo Documentation

Object[Analysis, BindingQuantitation]

Concentrations of the target analyte as calculated from analyte association rates with respect to standard curve.

Organizational Information

    Name

    Name of this Object.
    Format: Single
    Class: String
    Programmatic Pattern: _String
    Pattern Description: A string.

    ID

    ID of this Object.
    Format: Single
    Class: String
    Programmatic Pattern: _String
    Pattern Description: The ID of this object.

    Object

    Object of this Object.
    Format: Single
    Class: Expression
    Programmatic Pattern: Object[Analysis, BindingQuantitation, _String]
    Pattern Description: The object reference of this object.

    Type

    Type of this Object.
    Format: Single
    Class: Expression

    Notebook

    Notebook this object belongs to.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link
    Pattern Description: An object of that matches ObjectP[Object[LaboratoryNotebook]].

    Author

    The person who ran the analysis.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link
    Relation: Object[User]

General

Analysis & Reports

    SamplesInConcentrations

    For each member of SamplesIn, the concentrations calculated from the standard curve.
    Format: Multiple
    Class: VariableUnit
    Programmatic Pattern: Gram Hold[GreaterP[0 Nano Molar] | GreaterP[0 Milli ----------]] Milliliter

    ConcentrationDistributions

    For each member of SamplesIn, the statistical distribution of the analyte concentrations calculated by this analysis.
    Format: Multiple
    Class: Expression
    Programmatic Pattern: DistributionP[]

    Rate

    For each member of SamplesIn, the fitted values the binding rate of each sample.
    Format: Multiple
    Class: Real
    Unit: 1 reciprocal second
    Programmatic Pattern: NumericP

    RateError

    For each member of SamplesIn, the error in the fitted analyte association rates calculated by this analysis.
    Format: Multiple
    Class: Real
    Unit: 1 reciprocal second
    Programmatic Pattern: NumericP

    EquilibriumResponse

    For each member of SamplesIn, the fitted values the equilibrium response of each sample.
    Format: Multiple
    Class: Real
    Unit: 1 nanometer
    Programmatic Pattern: RangeP[-1000 Nano Meter, 1000 Nano Meter]

    EquilibriumResponseError

    For each member of SamplesIn, the error in the equilibrium response calculated by this analysis.
    Format: Multiple
    Class: Real
    Unit: 1 nanometer
    Programmatic Pattern: GreaterP[0 Nanometer]

    StandardCurveFitAnalysis

    The fitting analysis of the standard curve.
    Format: Single
    Class: Link
    Programmatic Pattern: _Link
Last modified on Mon 26 Sep 2022 15:43:43